Results 81 to 90 of about 39,891 (249)

Cirsium arvense management with electrical weed control and clopyralid

open access: yesPest Management Science, EarlyView.
Electrical weed control (EWC) treatments reduced Cirsium arvense biomass by ≤95% and suppressed new shoot emergence by 70–95%, achieving control comparable to clopyralid. Sequential or integrated applications enhanced efficacy, demonstrating EWC's potential as a nonchemical tool for perennial weed management in orchard systems.
Luisa Carolina Baccin   +1 more
wiley   +1 more source

Experimental Test bed to De-Risk the Navy Advanced Development Model [PDF]

open access: yes, 2017
This paper presents a reduced scale demonstration test-bed at the University of Texas’ Center for Electromechanics (UT-CEM) which is well equipped to support the development and assessment of the anticipated Navy Advanced Development Model (ADM).
Feng, X   +6 more
core   +1 more source

All‐sky assimilation impacts of the Tomorrow.io microwave sounder constellation on global weather forecasts

open access: yesQuarterly Journal of the Royal Meteorological Society, EarlyView.
Key Findings: An assimilation methodology is established for the Tomorrow.io microwave sounder (TMS) flying on CubeSats in sun‐synchronous and inclined orbits, and in all cloud scenes. The TMS has a significant impact on weather forecast lead times up to 3 days in the Tropics in a research‐quality numerical weather prediction setting, and yields water ...
Jonathan J. Guerrette   +3 more
wiley   +1 more source

Reducing the Impacts of Distributed Generation in Transmission & Distribution Networks Protection Using Fault Current Limiters [PDF]

open access: yesEngineering and Technology Journal, 2013
Increase in power generation capacity of electric power systems has lead to increase in the fault current level. In some cases fault current levels are exceeding the interrupting capability of existing transmission and distribution substations circuit ...
Wafaa Saeed
doaj   +1 more source

Size Scaling of the Electrochemical Performance of Ti3C2Tx MXene Microelectrode Arrays for Electrophysiological Recording and Stimulation

open access: yesSmall, EarlyView.
This study evaluates Ti3C2Tx MXene‐based microelectrodes across a range of diameters (25–500 µm) and elucidates their recording and stimulation capabilities for bioelectronic applications. Several electrochemical measurements—supported further by equivalent‐circuit modeling—revealed enhanced recording and stimulation capabilities of the MXene ...
Spencer R. Averbeck   +6 more
wiley   +1 more source

Thermally responsive mechanical actuator [PDF]

open access: yes, 1973
Device built for use in heat control, heat measurement, and mechanical actuation by heat include thermometers, thermostats, safety switches, circuit breakers, and mechanical actuators.
Madey, J. M.
core   +1 more source

Investigation of the Simplified Equivalent Circuit Model of the Post‐Arc Sheath Stage in DC Vacuum Circuit Breakers

open access: yesHigh Voltage, EarlyView.
ABSTRACT This paper presents a simplified equivalent circuit model (ECM) for the post‐arc sheath stage in DC vacuum circuit breakers and outlines the method for calculating circuit parameters using the particle‐in‐cell Monte Carlo collision (PIC‐MCC) method. The post‐arc sheath is modelled as a parallel combination of a variable resistor and a variable
Xubin Li   +5 more
wiley   +1 more source

Rating of Oil Circuit Breakers [PDF]

open access: yesTransactions of the American Institute of Electrical Engineers, 1916
Paper points out several difficulties, which are encountered in the rating of actual circuit breakers, but generally favors that these ratings be on the basis of the current to be opened in the arc at the operating voltage of the system.
openaire   +2 more sources

Logic-controlled solid state switchgear for 270 volts dc [PDF]

open access: yes
A feasibility study to design and demonstrate solid state switchgear in the form of circuit breakers and a power transfer switch is described. The switchgear operates on a nominal 270 V dc circuit and controls power to a load of up to 15 amperes.
Buchanan, E. E., Jr.   +2 more
core   +1 more source

Logic controlled solid state switchgear [PDF]

open access: yes, 1973
Logic controlled solid state circuit breakers and power transfer switches have been designed and built to demonstrate their use for 270 V dc power systems. This switchgear provides remote operation, automatic current level, and operates several orders of
Buchanan, E., Waddington, D.
core   +1 more source

Home - About - Disclaimer - Privacy