Results 131 to 140 of about 93,203 (297)
Monotone Circuit Complexity of Matching
We show that the perfect matching function on $n$-vertex graphs requires monotone circuits of size $\smash{2^{n^{Ω(1)}}}$. This improves on the $n^{Ω(\log n)}$ lower bound of Razborov (1985). Our proof uses the standard approximation method together with a new sunflower lemma for matchings.
Bruno Cavalar +4 more
openaire +3 more sources
Optoelectronic synaptic devices based on solution‐processed molecular telluride GST‐225 phase‐change inks are demonstrated for three‐factor learning. A global optical signal broadcast through a silicon waveguide induces non‐volatile conductance updates exclusively in locally electrically flagged memristors.
Kevin Portner +14 more
wiley +1 more source
Judicial improvement and trade structure optimization are important elements in achieving a high level of openness. This paper develops a theoretical framework on the impact of local protectionism on market integration and export technical complexity ...
Xin Gao, Shuo Kong
doaj +1 more source
ABSTRACT Electronic waste has emerged as a major environmental challenge, driven by the massive consumption and a limited lifetime of modern electronic devices, stimulating the development of sustainable electronics. Here, an all‐biomaterial gelatin‐choline‐citric acid ([Ch][CA]) ionogel is developed as an active binder to realize self‐sintered ...
Lin Guo +10 more
wiley +1 more source
MOOSE: A Physically Based Compact DC Model of SOI LDMOSFETs for Analogue Circuit Simulation
In this paper, we present a compact model for silicon-on-insulator (SOI) laterally double diffused (LD) MOSFETs. The model is complete insofar as it uses no subcircuits, and is intended to predict device operation in all regions of bias.
Swanenberg, M. +4 more
core
A soft, dual‐channel hydrogel patch enables simultaneous detection of wound temperature and strain by integrating ion‐diffusion‐mediated thermoelectric and resistive sensing. The conformal design maintains stable performance during motion, capturing subtle inflammatory and mechanical changes for continuous wound monitoring.
Yu Fang +7 more
wiley +1 more source
A compostable PGS soft surgical robot with interchangeable modules integrates transient Mo tactile and Si thermal sensors for dual feedback. The device preserves its function after clinical‐grade sterilization, demonstrates stable actuation and cardiac tissue grasping with real‐time in vivo pulsatile monitoring, and biodegrades post‐use with soil‐safe,
Minseong Chae +27 more
wiley +1 more source
Circuit complexity of quantum access models for encoding classical data
How to efficiently encode classical data is a fundamental task in quantum computing. While many existing works treat classical data encoding as a black box in oracle-based quantum algorithms, their explicit constructions are crucial for the efficiency of
Xiao-Ming Zhang, Xiao Yuan
doaj +1 more source
Omnipolar Magnetic Field Detection by Superlattice‐Based Hall Sensor
Magnetic‐field‐induced electronic switching is demonstrated in unit‐cell‐engineered La0.7Sr0.3MnO3–BiFeO3 superlattices. Distinct substrate terminations modify magnetic and transport properties. Hall resistance measurements show omnipolar, hysteretic anomalous Hall switching above the Curie temperature, arising from Fe─Mn interfacial exchange, enabling
Mark Huijben +6 more
wiley +1 more source
Spatially Modulated Morphotropic Phase Boundaries in a Compressively Strained Multiferroic Thin Film
ABSTRACT The coexisting rhombohedral‐like (R′, MA) and tetragonal‐like (T′, MC) monoclinic phases in compressively strained bismuth ferrite thin films exhibit exceptional piezoelectric and magnetic properties. While previous studies have largely focused on probing the morphotropic phase boundaries (MPBs) comprising ordered R′/T′ twins, their self ...
Ting‐Ran Liu +7 more
wiley +1 more source

