Study on the Influences of Multiple Parameters With Uncertainty in the Clamp-On Ultrasonic Flowmeter [PDF]
For a clamp-on ultrasonic flowmeter based on transit-time differential method, the flow rate calculation model with flow velocity correction is established and verified by experiments carried out in a flow standard facility.
Huichao Shi +3 more
doaj +6 more sources
Research on Measurement Error Distribution and Optimization Measurement Method of Clamp-On Ultrasonic Flowmeter in Downstream Pipeline Disturbance [PDF]
Clamp-on ultrasonic flowmeters serve as an important tool for on-site testing of gas flow meters. However, its accuracy is significantly affected by the actual flow field, thus limiting its application scenarios. To address this issue, this study focuses
Zhongzhi Yang +5 more
doaj +5 more sources
Energy management in industrial plants requires measurements of the steam flow rates at each usage location. A clamp-on ultrasonic flowmeter can be used to effectively measure the steam flow rates in existing pipes.
Hideki MURAKAWA +6 more
doaj +6 more sources
A Study on Ultrasonic Wave Detection Method for Clamp-On Ultrasonic Gas Flowmeter
We examine clamp-on ultrasonic flowmeters for gas, in particular, low-pressure gases at atmospheric pressure.
Kouki Nagamune
exaly +3 more sources
Easy-Setup Clamp-On Ultrasonic Flowmeter
A clamp-on ultrasonic flowmeter is the only flowmeter that can be installed on existing pipelines without draining and plumbing. In conventional clamp-on ultrasonic flowmeters, the relative position of transducers depends heavily on the properties of the pipe on which the transducers are mounted.
Minako Terao +2 more
exaly +3 more sources
Development of a Tomography Clamp-On Ultrasonic Flowmeter for Measuring Biased Flows
Shuichi Ohmori +2 more
exaly +3 more sources
A Propagation Time Difference Evaluation for a Clamp-On Ultrasonic Flowmeter for Low-Pressure Gas
Abstract We have been studying the development of a clamp-on ultrasonic flowmeter for measuring the gas flow rate, especially at low-pressure gas such as atmospheric pressure. In this study, we evaluated the propagation time difference of ultrasonic wave for measuring the airflow at atmospheric pressure. We placed a pair of ultrasonic
Kouki Nagamune
exaly +3 more sources
Automatic Calibration of Clamp-On Ultrasonic Flowmeter Based on Fieldbus Control System
In practical application, some flowmeters are not allowed to be calibrated off-line periodically, thus on-line calibration is necessary to be implemented in workplace [1]. As a non-invasive flowmeter, the clamp-on ultrasonic flowmeters are widely used in
Yong Mei Huang
exaly +3 more sources
Influence of Flow Disturbances behind the 90° Bend on the Indications of the Ultrasonic Flow Meter with Clamp-On Sensors on Pipelines [PDF]
The subject matter of the article concerns velocities/flow rate measurements in the area of disturbed flows-behind the 90° bend. They were conducted by means of an ultrasonic flowmeter with clamp-on sensors on pipeline, for water and two different ...
Piotr Synowiec +4 more
doaj +2 more sources
Measurement of Steam Flow Rates Using a Clamp-On Ultrasonic Flowmeter With Various Wetness Fractions
Most of the heat in industrial plants is supplied by steam. To minimize energy waste, measuring the steam flow rates in existing pipes is important. Clamp-on ultrasonic flowmeters are used for this purpose, for which the sensors are attached to the pipe ...
Hideki Murakawa +2 more