Results 11 to 20 of about 471 (134)

Ultrasonic propagation analysis of a tomography clamp-on ultrasonic flowmeter

open access: yesThe Proceedings of the Fluids engineering conference, 2021
Takeshi Suzuki   +4 more
semanticscholar   +2 more sources

Linearity Error in Clamp-On Ultrasonic Flowmeters Due to the Installation on Pipes Made of Dispersive Materials

open access: yes2017 IEEE International Instrumentation and Measurement Technology Conference (I2MTC), 2017
This article analyses and explains the implications that dispersive materials have over the linearity in flow measurement when a Clamp-on ultrasonic flowmeter is used. This is of capital importance because dispersive materials are commonly used in the manufacture of transducer wedges and pipes.
Jordi Salazar   +2 more
exaly   +4 more sources

Development of a Clamp-on Ultrasonic Flowmeter using Tomography Method

open access: yesThe Proceedings of the Fluids engineering conference, 2020
Asahi Matsuo   +5 more
semanticscholar   +2 more sources

Validation of Intravoxel Incoherent Motion MRI Using Perfused Explanted Human Livers. [PDF]

open access: yesMagn Reson Med
ABSTRACT Purpose Evaluate the feasibility of using perfused explanted human livers for validating intravoxel incoherent motion (IVIM). Methods Eight (n = 8) explanted livers from deceased donors were obtained. The portal vein and hepatic artery of each explanted liver were connected to a perfusion system.
Simchick G   +6 more
europepmc   +2 more sources

Improvement of the accuracy of a Clamp-on Ultrasonic Flowmeter for Gas

open access: yesThe Proceedings of Mechanical Engineering Congress, Japan, 2016
Hiroshi Nishiguchi   +2 more
semanticscholar   +2 more sources

Prevention of thrombus formation in blood pump by mechanical circular orbital excitation of impeller in magnetically levitated centrifugal pump. [PDF]

open access: yesArtif Organs, 2023
Circular orbital excitation can prevent thrombus formation in blood pump. The proposed method was more effective than simple reciprocating vibration (previous study). The combination of proposed method and conventional anticoagulant therapy would show better effect.
Hatakenaka K   +4 more
europepmc   +2 more sources

Measurement of steam flow rate using clamp-on ultrasonic flowmeter

open access: yesThe Proceedings of the Fluids engineering conference, 2018
Shuhei Ichimura   +5 more
semanticscholar   +2 more sources

Application of the Clamp-on Ultrasonic Steam Flowmeter to the Site

open access: yesThe Proceedings of the National Symposium on Power and Energy Systems, 2017
H. Sasaki   +3 more
semanticscholar   +2 more sources

On the Use of Ultrasonic Flowmeters for Cooling Energy Metering and Sub-Metering in Direct Expansion Systems

open access: yesEnergies, 2023
The Energy Efficiency Directive (EED, Directive 2012/27/EU) has made mandatory the installation of individual metering systems in the case of buildings with centralized heating/cooling and hot water sources (multi-apartment and multi-purpose buildings ...
Ciro Aprea   +6 more
doaj   +1 more source

The Thigh Saphenous Vein Versus the Calf Saphenous Vein: Searching for the Optimal Conduit for Coronary Artery Bypass Grafting. [PDF]

open access: yesCatheter Cardiovasc Interv
ABSTRACT Background The quality of saphenous vein (SV) grafts can vary depending on the site from which they are harvested. However, few studies have compared SV grafts harvested from the thigh with those harvested from the calf to explore which is more appropriate for use in coronary artery bypass grafting (CABG). In this study, we evaluated the graft
Chen A, Pan K.
europepmc   +2 more sources

Home - About - Disclaimer - Privacy