Results 31 to 40 of about 299 (260)

Conductive Bonding and System Architectures for High‐Performance Flexible Electronics

open access: yesAdvanced Functional Materials, EarlyView.
This review outlines bonding technologies and structural design strategies that support high‐performance flexible and stretchable electronics. Bonding approaches such as surface‐activated bonding and anisotropic conductive films, together with system‐level architectures including buffer layers and island‐bridge structures, possess distinct mechanical ...
Kazuma Nakajima, Kenjiro Fukuda
wiley   +1 more source

Electrocatalytic Reduction of CO2 to Ethylene: Catalyst Design and Synchrotron‐Based Characterizations

open access: yesAdvanced Functional Materials, EarlyView.
This review evaluates strategies for electrochemical CO2 reduction to ethylene, focusing on copper‐based catalyst design and microenvironment modulation to achieve industrial‐grade performance. By leveraging operando synchrotron‐based characterizations, we provide a multiscale understanding of dynamic structural transformations and key reaction ...
Meng Zhang, Zuolong Chen, Yimin A. Wu
wiley   +1 more source

Computational Modeling Meets 3D Bioprinting: Emerging Synergies in Cardiovascular Disease Modeling

open access: yesAdvanced Healthcare Materials, EarlyView.
Emerging advances in three‐dimensional bioprinting and computational modeling are reshaping cardiovascular (CV) research by enabling more realistic, patient‐specific tissue platforms. This review surveys cutting‐edge approaches that merge biomimetic CV constructs with computational simulations to overcome the limitations of traditional models, improve ...
Tanmay Mukherjee   +7 more
wiley   +1 more source

Melt Electrowriting High Resolution Poly(ethylene‐co‐vinyl acetate) Scaffolds for Soft Tissue Engineering

open access: yesAdvanced Healthcare Materials, EarlyView.
This work pioneers melt electrowriting (MEW) of polyethylene vinyl acetate (PEVA) to fabricate ultra‐compliant, high‐resolution scaffolds. By integrating microscale precision with soft tissue‐like biomechanics, PEVA overcomes stiffness‐driven limitations of conventional MEW polymers, establishing a mechanically biomimetic platform for soft tissue ...
Finn Snow   +9 more
wiley   +1 more source

Manipulating density pedestal structure to improve core–edge integration towards low collisionality

open access: yesNuclear Fusion
DIII-D experiments have achieved promising core–edge integrated plasma scenarios which combine a high-temperature low-collisionality pedestal (pedestal top temperature T _e _,ped > 0.8 keV and collisionality ν * _ped < 1) with a partially detached ...
H.Q. Wang   +18 more
doaj   +1 more source

3D‐Printed Gastrointestinal Stents: In Vivo Evaluation in a Swine Small Bowel Perforation Model

open access: yesAdvanced Healthcare Materials, EarlyView.
Gastrointestinal fistulae and perforations can lead to severe complications including sepsis and patient death. In this work, the efficacy of 3D‐printed gastrointestinal stents composed of poly‐lactic‐acid (PLA) was evaluated in an in vivo swine model.
Gweniviere Capron   +9 more
wiley   +1 more source

POM‐Based Water Splitting Catalyst Under Acid Conditions Driven by Its Assembly on Carbon Nanotubes

open access: yesAdvanced Materials, EarlyView.
A newly‐engineered POM‐based electrocatalyst incorporating non‐innocent counter cations exhibits fast kinetics for either the OER or HER under strongly acidic conditions (1 m H2SO4), depending on whether it is assembled on carbon nanotubes (1@CNT) or physically mixed with them (1/CNT). In water‐splitting tests using a two‐electrode setup, these systems
Eugenia P. Quirós‐Díez   +8 more
wiley   +1 more source

Investigating the effect of BT direction on W source-to-core pathways during the SAS-VW campaign on DIII-D

open access: yesNuclear Materials and Energy
Experiments using the V-shaped closed slot tungsten (W) coated SAS-VW divertor in DIII-D studied the effects of the BT direction on core contamination of eroded tungsten from a closed slot divertor configuration.
J.D. Mateja   +12 more
doaj   +1 more source

Architecture of an All‐In‐One Microfluidic Platform for Accelerated Cancer Seeding, Enhanced Spheroid Formation, and Dynamic Drug Screening Trials

open access: yesAdvanced Materials Technologies, EarlyView.
An all‐in‐one microfluidic platform consists of two‐layered PDMS channels integrated with a hydrogel microwell array. This platform enables flow‐driven tumor cell capture, enhanced spheroid formation within the microwells, and advective drug testing. ABSTRACT Effective cancer drug screening requires platforms that replicate the physiological complexity
Omar M. Rahman   +2 more
wiley   +1 more source

Role of turbulent separatrix tangle in the improvement of the integrated pedestal and heat exhaust issue for stationary-operation tokamak fusion reactors

open access: yesNuclear Fusion
The magnetic separatrix surface is designed to provide the final and critical confinement to the hot stationary-operation core plasma in modern tokamak reactors in the absence of an external magnetic perturbation (MP) or transient magneto-hydrodynamic ...
C.S. Chang   +7 more
doaj   +1 more source

Home - About - Disclaimer - Privacy