Results 141 to 150 of about 307 (173)
Some of the next articles are maybe not open access.
Coherent Doppler Lidars for Wind Sensing in the Atmosphere
Topical Meeting on Optical Techniques for Remote Probing of the Atmosphere, 1983The development of wind sensing coherent Doppler lidars over the past 15 years has progressed from CW homodyne to sophisticated, pulsed heterodyne systems.
openaire +1 more source
Potential for coherent Doppler wind velocity lidar using neodymium lasers
Applied Optics, 1984Existing techniques for the frequency stabilization of Nd:YAG lasers operating at 1.06 micron, and the high-gain amplification of radiation at that wavelength, make possible the construction of a coherent Doppler wind velocity lidar using Nd:YAG. Velocity accuracy and range resolution are better at 1.06 micron than at 10.6 microns at the same level of ...
T J, Kane, B, Zhou, R L, Byer
openaire +2 more sources
Wind profiling for a coherent wind Doppler lidar by an auto-adaptive background subtraction approach
Applied Optics, 2017Auto-adaptive background subtraction (AABS) is proposed as a denoising method for data processing of the coherent Doppler lidar (CDL). The method is proposed specifically for a low-signal-to-noise-ratio regime, in which the drifting power spectral density of CDL data occurs.
Yanwei, Wu +4 more
openaire +2 more sources
Combining direct and coherent detection for Doppler wind lidar
SPIE Proceedings, 2004Using a combination of two modest sized coherent and direct detection Doppler lidars may offer significant advantages over the single detection method approaches. All space-based Doppler wind lidar proposed missions to date have been based upon a single detection scheme, either coherent (WINDSAT, LAWS, SPARCLE, JEM/CDL) or direct (Zephyr, ALADIN, ADM ...
openaire +1 more source
Tropospheric Wind Measurements with an Airborne Scanning Coherent Doppler Lidar
Optical Remote Sensing of the Atmosphere, 1997Since the first remote wind measurements in 1967, coherent Doppler lidar has become established as a unique tool for atmospheric research. Remote sensing of the two-dimensional horizontal wind field with airborne coherent Doppler lidar was demonstrated in 1981 using a low-energy scanning CO2 lidar.1 The scanner and operations control system were ...
Jeffry Rothermel +6 more
openaire +1 more source
Characterization of turbulent wake of wind turbine by coherent Doppler lidar
SPIE Proceedings, 2014The indispensable access to real turbulent wake behavior is provided by the pulsed coherent Doppler Light Detection and Ranging (LIDAR) which operates by transmitting a laser beam and detecting the radiation backscattered by atmospheric aerosol particles. The Doppler shift in the frequency of the backscattered signal is analyzed to obtain the line-of-
Songhua Wu +8 more
openaire +1 more source
1-bit sampling acquisition method for coherent Doppler wind lidar
Applied OpticsCoherent Doppler wind lidar (CDWL) is a critical technology in wind measurement. However, the large volume of data generated during detection poses a significant challenge for data acquisition and processing systems. While 1-bit sampling using a comparator (CMP) has been proposed to reduce FPGA resource consumption ...
Baolin Chen +5 more
openaire +2 more sources
Basic principles of pulsed-wind Doppler lidars with multitime coherence
Laser Physics, 2008A concept of multitime coherence (MTC) of optical beams is proposed. Two versions of fiber multiplicator topologies are presented, which are intended for the generation of multiple fiber pulses (MFP) possessing the MTC property. The fiber multiplicators may be a useful tool for Doppler laser anemometry of spatially separated scattering objects ...
G. G. Matvienko +2 more
openaire +1 more source
Performance of a 2-µm Coherent Doppler Lidar for Wind Measurements
Journal of Atmospheric and Oceanic Technology, 1994Abstract Measurements of boundary layer winds are presented using a 2-µm coherent Doppler lidar and the optimal performance of the maximum likelihood estimator. The systematic error for single-shot estimates was estimated as 3.6 cm s−1 using measurements from a stationary hard target. The estimation error for measurements of the radial component of the
Rod Frehlich +2 more
openaire +1 more source
Coherent Doppler wind lidar for the Japanese experimental module of the ISS
Optical Remote Sensing, 2003A feasibility study has been done for a space-borne 2micron coherent Doppler lidar system aiming at demonstration of the technology onboard the Japanese Experiment module of the International Space Station. We are also developing an airborne coherent Doppler lidar system for simulation of the Doppler lidar measurement in space.
Toshikazu Itabe, Kohei Mizutani
openaire +1 more source

