Results 71 to 80 of about 24,396 (207)

Fibrin sheath of a peripherally inserted central catheter undepicted with gray-scale (real-time B-mode) ultrasonography: A case report

open access: yesRadiology Case Reports, 2018
An 11-year-old male was admitted to our hospital with the acute exacerbation of chronic heart failure. A peripherally inserted central catheter (PICC) was inserted from the left forearm.
Naoko Mogi, MD   +5 more
doaj   +1 more source

Strain and Shear Wave Elastography in Thyroid Nodules: Tissue Stiffness as a Complementary Risk Marker for Differentiating Benign, Indeterminate, and Malignant Cytology

open access: yesHead &Neck, EarlyView.
ABSTRACT Objective To evaluate the diagnostic performance of shear wave elastography (SWE) and strain elastography (SE) as complementary techniques to conventional B‐mode ultrasound for differentiating benign, indeterminate, and malignant thyroid nodules. Methods This prospective cross‐sectional study included 208 thyroid nodules evaluated using B‐mode
Kairo Alexandre Alves Silveira   +5 more
wiley   +1 more source

Longest survivor of pulmonary atresia with ventricular septal defect without surgical intervention

open access: yes
ESC Heart Failure, Volume 12, Issue 2, Page 1499-1507, April 2025.
Sang Zhou   +5 more
wiley   +1 more source

Research progress on the use of the optical coherence tomography system for the diagnosis and treatment of central nervous system tumors

open access: yesIbrain, Volume 11, Issue 1, Page 3-18, Spring 2025.
With the advantages of high‐resolution imaging, efficient image acquisition, intraoperative real‐time detection, and radiation‐free and noninvasive characteristics, optical coherence tomography (OCT) provides accurate diagnosis and effective intraoperative guidance for the minimally invasive diagnosis and treatment of central nervous system (CNS ...
Jiuhong Li   +10 more
wiley   +1 more source

Piezoelectric Materials in Medical Ultrasound: A Comprehensive Review From Fundamentals to Translational Prospects

open access: yesInformation &Functional Materials, EarlyView.
Piezoelectric materials are reviewed as active platforms for medical ultrasound, bridging electromechanical fundamentals, transducer architectures, and biomedical applications. Material–device co‐design is emphasized as the key to high‐performance diagnosis, therapy, monitoring, wearable ultrasound, and emerging ultrasound‐responsive functions ...
Jianan Li, Qing Wan
wiley   +1 more source

Clinical applications of ultrasonography in diagnosing head and neck swellings

open access: yesJournal of Oral and Maxillofacial Radiology, 2017
Background: Ultrasonography is well-known for its application in medicine, and has been recently gaining importance for its use in the orofacial region. Aims and Objective: The present study aims to determine the efficacy of ultrasonography in diagnosing
Jigna S Shah, Vijay K Asrani
doaj   +1 more source

Obstetrics and gynecology devices designed for low‐ and middle‐income countries: A narrative review

open access: yesInternational Journal of Gynecology &Obstetrics, Volume 169, Issue 1, Page 71-80, April 2025.
Abstract There are many barriers contributing to poor health outcomes for women in low‐ and middle‐income countries (LMICs), one of which is the lack of necessary medical devices. Presently, the development of various kinds of devices intended to improve women's health outcomes specifically in LMICs remains underrepresented in the literature; therefore,
Dhanalakshmi Thiyagarajan   +2 more
wiley   +1 more source

IS PRIAPISM AFTER PENIL COLOR DOPPLER ULTRASONOGRAPHY PREDICT WITH DOPPLER FINDINGS?

open access: yesUrology Research and Practice, 2019
-
E. Yeni   +5 more
doaj   +2 more sources

Carotid artery color Doppler ultrasonography and plasma levels of lipoprotein-associated phospholipase A2 and cystatin C in arteriosclerotic cerebral infarction

open access: yesJournal of International Medical Research, 2019
Objective This study was performed to evaluate the clinical application value of carotid artery color Doppler ultrasonography and the plasma levels of lipoprotein-associated phospholipase A2 (Lp-PLA2) and cystatin C (Cys C) in the diagnosis and treatment
Lei Huang, Shengguo Yao
doaj   +1 more source

Home - About - Disclaimer - Privacy