Results 21 to 30 of about 395,266 (293)
Galvanically isolated voltage measurements are becoming increasingly important for the characterization of converter systems with fast switching Wide-Bandgap (WBG) semiconductors. A very high Common Mode Rejection Ratio (CMRR) $> 80$dB for frequencies
Pascal S. Niklaus +4 more
doaj +1 more source
Artifact-Aware Analogue/Mixed-Signal Front-Ends for Neural Recording Applications [PDF]
This paper presents a brief review of techniques to overcome the problems associated with artifacts in analog frontends for neural recording applications.
Delgado Restituto, Manuel +2 more
core +1 more source
Design of current sources for load common mode optimization
Bioimpedance measurement systems often use the Howland current sources to excite the biological material under study. Usually, difference or instrumentation amplifiers are used to measure the resulting voltage drop on this material.
Sirtoli Vinicius G +2 more
doaj +1 more source
Bose-Einstein Condensate Comagnetometer [PDF]
We describe a comagnetometer employing the $f=1$ and $f=2$ ground state hyperfine manifolds of a $^{87}$Rb spinor Bose-Einstein condensate as co-located magnetometers.
Gomez, Pau +5 more
core +2 more sources
Article highlights Highly accurate amplifier is designed to detect very weak signals of information (such as biomedical signals), and amplify them for further processing.
Soma Ahmadi +5 more
doaj +1 more source
Common-Mode Driven Synchronous Filtering of the Powerline Interference in ECG
Powerline interference (PLI) is a major disturbing factor in ground-free biopotential acquisition systems. PLI produces both common-mode and differential input voltages.
Tatyana Neycheva +2 more
doaj +1 more source
A 0.3 V, Rail-to-Rail, Ultralow-Power, Non-Tailed, Body-Driven, Sub-Threshold Amplifier
A novel, inverter-based, fully differential, body-driven, rail-to-rail, input stage topology is proposed in this paper. The input stage exploits a replica bias control loop to set the common mode current and a common mode feed-forward strategy to set its
Francesco Centurelli +3 more
doaj +1 more source
A High TCMRR, Inherently Charge Balanced Bidirectional Front-End for Multichannel Closed-Loop Neuromodulation [PDF]
This paper describes a multichannel bidirectional front-end for implantable closed-loop neuromodulation. Stimulation artefacts are reduced by way of a 4-channel H-bridge current source sharing stimulator front-end that minimizes residual charge drops in ...
Delgado Restituto, Manuel +4 more
core +1 more source
Robust Smartphone Assisted Biosensing Based on Asymmetric Nanofluidic Grating Interferometry
Point-of-care systems enable fast therapy decisions on site without the need of any healthcare infrastructure. In addition to the sensitive detection, stable measurement by inexperienced persons outside of laboratory facilities is indispensable.
Foelke Purr +5 more
doaj +1 more source
Manufacturing Tolerance Analysis of Deep-Ridged 90° Hybrid Based on InP 4 × 4 MMI
An optical 90° hybrid based on an InGaAsP/InP deep-ridged 4 × 4 multimode interference (MMI) coupler is proposed and fabricated. Manufacturing tolerances on structural parameters of the 90° hybrid including multimode waveguide width and length, waveguide
Ziqing Lu +4 more
doaj +1 more source

