Results 81 to 90 of about 395,266 (293)
Development of a Low-Noise High Common-Mode-Rejection Instrumentation Amplifier [PDF]
Several previously used instrumentation amplifier circuits were examined to find limitations and possibilities for improvement. One general configuration is analyzed in detail, and methods for improvement are enumerated.
Blalock, T. V. +2 more
core +1 more source
Adenovirus infection in pediatric liver transplant recipients [PDF]
A retrospective review of adenoviral infection in pediatric liver transplant recipients was done at Children’s Hospital of Pittsburgh to define its epidemiology and clinical importance.
Green, M +3 more
core +2 more sources
This work explores Li‐substituted P2 layered oxides for Na‐ion batteries by crystallographic and electrochemical studies. The effect of lithium on superstructure orderings, on phase transitions during synthesis and electrochemical cycling and on the interplay of O‐ versus TM‐redox is revealed via various advanced techniques, including semi‐simultaneous
Mingfeng Xu +5 more
wiley +1 more source
2.4-GHz CMOS Power Amplifier With Common-Mode Self-Rejection Technique to Suppress Even Harmonics
In this study, we propose a common-mode self-rejection (CMSR) technique to improve the linearity of CMOS differential power amplifiers. The proposed CMSR technique is implemented through a matching network consisting of a Guanella transformer between the
Donghwan Seo +4 more
doaj +1 more source
The LISA Pathfinder mission to space employs an optical metrology system (OMS) at its core to measure the distance and attitude between two freely floating test-masses to picometer and nanorad accuracy, respectively, within the measurement band of [1 mHz,
Flatscher, Reinhold +1 more
core +1 more source
A Fully Differential CMOS Potentiostat [PDF]
A CMOS potentiostat for chemical sensing in a noisy environment is presented. The potentiostat measures bidirectional electrochemical redox currents proportional to the concentration of a chemical down to pico-ampere range.
Genov, Roman, Nazari, Meisam Honarvar
core +1 more source
Magnetic Control of Chiral Hybridized Phonon Magnetic Moments in Ferrimagnets Fe2‐xZnxMo3O8
Helicity‐resolved magneto‐Raman spectroscopy reveals magnetic control of chiral phonon magnetic moments in polar ferrimagnet (ZnxFe2−xMo3O₈). Large spontaneous zero‐field phonon splittings, selective phonon–magnon coupling, and asymmetric Zeeman responses demonstrate that phonon chirality is governed by magnon‐phonon coupling and magnetization.
Youngsu Choi +8 more
wiley +1 more source
Common Mode Rejection Calculations on the Debuncher Upgrade [PDF]
The 4-8 GHz Transverse Debuncher Cooling Systems are power limited. Misalignments and imperfections in the transverse pickup arrays will generate a longitudinal signal in addition to the betatron signal. This longitudinal signal can use up a significant fraction of the precious TWT power if the imperfections are large enough.
openaire +2 more sources
Automat optical inspection (AOI) techniques in semiconductor fabrication can be leveraged in battery manufacturing, enabling scalable detection and analysis of electrode‐ and cell‐level imperfections through AI‐driven analytics and a digital‐twin framework.
Jianyu Li, Ertao Hu, Wei Wei, Feifei Shi
wiley +1 more source
The Monte Carlo Program KoralW version 1.51 and The Concurrent Monte Carlo KoralW&YFSWW3 with All Background Graphs and First Order Corrections to W-Pair Production [PDF]
The version 1.51 of the Monte Carlo (MC) program KoralW for all $e^+e^-\to f_1\bar f_2 f_3\bar f_4$ processes is presented. The most important change since the previous version 1.42 is the facility for writing MC events on the mass storage device and re ...
Accomando +42 more
core +2 more sources

