Results 61 to 70 of about 395,266 (293)
DC biased input stage with differential photocurrent sensing for VLC front-ends [PDF]
The reverse bias voltage across the PIN photodiode is essential for the photodiode to operate in the photoconductive mode. This paper presents an input bias stage with differential photocurrent sensing for VLC front-ends.
Basha, Majed, Binns, Richard
core +2 more sources
Screening Routine Clinical Notes for Epilepsy Surgery Candidates Using Large Language Models
ABSTRACT Objective Epilepsy surgery is severely underutilized despite proven efficacy, with substantial under‐referral of eligible patients in routine clinical practice. This study evaluated the potential role of large language models (LLMs) as decision‐support tools for screening unstructured clinical notes to identify epilepsy surgery candidates and ...
Uriel Fennig +9 more
wiley +1 more source
Phase detector for three-phase power factor controller [PDF]
A phase detector for the three phase power factor controller (PFC) is described. The phase detector for each phase includes an operational amplifier which senses the current phase angle for that phase by sensing the voltage across the phase thyristor ...
Nola, F. J.
core +1 more source
We propose a concept for future space gravity missions using cold atom interferometers for measuring the diagonal elements of the gravity gradient tensor and the spacecraft angular velocity.
Carraz, Olivier +4 more
core +1 more source
Objective Mycophenolate mofetil (MMF) use in limited cutaneous systemic sclerosis (lcSSc) is relatively uncommon because of the lower fibrotic burden and the predominance of vascular complications. In vitro observations and clinical data from transplanted patients suggest a protective effect of MMF on endothelial function.
Enrico De Lorenzis +77 more
wiley +1 more source
A magnetic quadrupole pick-up for the CERN PS [PDF]
In the LHC era, there will be a need to monitor and correct betatron mismatch between machines in a non-destructive way. For this purpose, a quadrupole pick-up has been designed for the CERN PS.
Chapman-Hatchett, A +2 more
core
The Martin-Puplett interferometer (MPI) is a differential Fourier transform spectrometer (FTS), measuring the difference between spectral brightness at two input ports.
D'Alessandro, Giuseppe +3 more
core +1 more source
The multilevel trigger system of the DIRAC experiment [PDF]
The multilevel trigger system of the DIRAC experiment at CERN is presented. It includes a fast first level trigger as well as various trigger processors to select events with a pair of pions having a low relative momentum typical of the physical process ...
A. Gorin +23 more
core +2 more sources
A Robust Adaptive One‐Sample‐Ahead Preview Super‐Twisting Sliding Mode Controller
Block Diagram of the Robust Adaptive One‐Sample‐Ahead Preview Super‐Twisting Sliding Mode Controller. ABSTRACT This article introduces a discrete‐time robust adaptive one‐sample‐ahead preview super‐twisting sliding mode controller. A stability analysis of the controller by Lyapunov criteria is developed to demonstrate its robustness in handling both ...
Guilherme Vieira Hollweg +5 more
wiley +1 more source
A new dual-band balanced bandpass filter based on magnetically coupled open-loop resonators in multilayer technology is proposed in this paper. The lower differential passband, centered at the Global Positioning System (GPS) L1 frequency, 1.575 GHz, was ...
Jose L. Medran del Rio +5 more
doaj +1 more source

