Results 21 to 30 of about 1,954,001 (140)
Hierarchical connection (HC) is a very attractive mode for ± 800 kV line commutated converter based ultra high voltage direct current (LCC-UHVDC) system connected to different AC voltage levels because of its ability to reduce the scale factor of a ...
Ali Aamir +4 more
doaj +1 more source
A controllable thyristor-based commutation failure inhibitor for LCC-HVDC transmission systems [PDF]
Commutation failure is a serious malfunction in line-commutated high voltage direct current (HVdc) converters which is mainly caused by the inverter ac faults, and results in a temporary interruption of transmitted power and damage to the converter ...
Mat Said, Dalila +5 more
core +3 more sources
Experimental and theoretical studies have confirmed that, relative to a one-shot voltage fault, a doubly-fed induction generator (DFIG) will suffer a greater transient impact during continuous voltage faults.
Zixuan Zheng +5 more
doaj +1 more source
To reduce the probability of commutation failure (CF) of a line commutated converter based high-voltage direct current (LCC-HVDC) transmission, a DC chopper topology composed of power consumption sub-modules based on thyristor full-bridge module (TFB ...
Chunyi Guo, Bo Liu, Chengyong Zhao
doaj +1 more source
An adaptive control of phase lock oscillator (PLO) is proposed to increase the ability of LCC-based HVDC systems to successfully recover from commutation failure, where the dynamic performance during the recovery process is improved.
Hongda Cai +3 more
doaj +1 more source
Commutation Failure Prediction for Multi-Infeed LCC-HVDC Systems Under Asymmetrical Faults
Commutation failure (CF) occurs frequently under inverter AC system faults. Around 70% of power system faults are Single-Line-to-Ground (SLG) faults that affect not only magnitudes but also phase angles of non-faulty phases.
Chunyan Cui +11 more
core +1 more source
This article presents a control strategy for a modular multilevel converter (MMC) to prevent commutation failure of a line-commutated converter (LCC), forming a three-terminal hybrid HVDC transmission system, where one LCC sending end is connected to the
Choongman Lee +3 more
doaj +1 more source
Earlier studies have reported some calculation methods for commutation failure fault level (CFFL) in line-commutated-converter based high-voltage direct current (LCC-HVDC) system under single-line-to-ground (SLG) faults.
Renlong Zhu +6 more
doaj +1 more source
With the rapid development of ultra-high-voltage (UHV) AC/DC, especially the step-by-step upgrading of the UHV DC transmission scale, security presents new challenges.
Li Sun, Hongbo Liu, Chenglian Ma
doaj +1 more source
Procedure analysis of UHVDC commutation failure
There may be a commutation failure during a fault or start-up of the UHVDC inverter side. The law of commutation failure process in UHVDC converter is studied here. First, the cause of inverter commutation failures is briefly introduced.
Chi Zhang +4 more
core +1 more source