Results 121 to 130 of about 8,831 (260)

Survey of normalized CTDIvol values across four major computed tomography vendors for use in the MIRDct software. [PDF]

open access: yesJ Appl Clin Med Phys
Dinwiddie LE   +13 more
europepmc   +1 more source

Velocity Spectrum Imaging Using Velocity Encoding Preparation Pulses

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose The goal of this article is to introduce a technique to measure the velocity distribution of water inside each voxel of an MR image. The method is based on the use of motion sensitizing gradients with changing first moment to encode velocity. As such, it is completely non‐invasive and requires no contrast injections.
Luis Hernandez‐Garcia   +2 more
wiley   +1 more source

Highly Reproducible, Vendor‐Agnostic, Motion‐Insensitive Liver PDFF Mapping at 0.55T, 1.5T, and 3T

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To develop and validate a vendor‐agnostic, motion‐insensitive proton‐density fat‐fraction (PDFF) quantification method. Methods Flip‐angle‐modulated (FAM) 2D chemical‐shift‐encoded (CSE) MRI for PDFF quantification was implemented in both the vendor‐agnostic platform Pulseq (“Pulseq‐FAM”) and one vendor‐specific platform (“GE‐specific ...
Jiayi Tang   +27 more
wiley   +1 more source

Standardization of MR Electrical Properties Tomography: A Guideline From the ISMRM Electro‐Magnetic Tissue Properties Study Group

open access: yes
Journal of Magnetic Resonance Imaging, EarlyView.
Stefano Mandija   +17 more
wiley   +1 more source

Accelerating Multiparametric Quantitative MRI Using Self‐Supervised Scan‐Specific Implicit Neural Representation With Model Reinforcement

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To develop a self‐supervised scan‐specific deep learning framework for reconstructing accelerated multiparametric quantitative MRI (qMRI). Methods We propose REFINE‐MORE (REference‐Free Implicit NEural representation with MOdel REinforcement), combining an implicit neural representation (INR) architecture with a model reinforcement ...
Ruimin Feng   +3 more
wiley   +1 more source

Development of anatomically variable digital Wistar rat phantoms for small animal imaging research. [PDF]

open access: yesMed Phys
Segars HE   +8 more
europepmc   +1 more source

Informed Dictionary‐Guided Monte Carlo Inversion for Robust and Reproducible Multidimensional MRI

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To develop a robust and efficient multidimensional MRI (MD‐MRI) data processing framework for accurately estimating joint frequency‐dependent diffusion‐relaxation distributions, while overcoming computational limitations and noise instability inherent to Monte Carlo (MC) inversion.
Joon Sik Park   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy