Artifacts in Computed Radiography
Computed radiography offers many advantages over the conventional radiography. With new technological breakthroughs and the development of systems that are more cost‐effective, there has been an increase in its use in the recent years. However, like all imaging modalities, one must be aware of the various artifacts that are likely to lead to ...
LTH Tan, KL Ong
exaly +3 more sources
Collimation and Exposure Parameter Influence Image Quality and Potential Radiation Dose to the Eye Lens of Personnel in Computed Radiography of the Canine Pelvis [PDF]
Introduction: The purpose of this study was to evaluate the effect of collimation on image quality and radiation dose to the eye lenses of the personnel involved in computed radiography of the canine pelvis.Materials and Methods: A retrospective study of
Malene Bisgaard +14 more
doaj +2 more sources
Image Reject Patterns in Computed Radiography: Insights From a Ghanaian Radiology Department [PDF]
Introduction Image reject analysis is a critical quality assurance (QA) tool in diagnostic imaging, helping to minimise unnecessary radiation exposure and improve imaging efficiency. This study evaluates image rejection patterns in a computed radiography
Bismark Ofori‐Manteaw +1 more
doaj +2 more sources
Comparison of Ultrasonographic, Radiographic, Computed Tomographic, and Ex Vivo Measurements of Feline Femoral Trochlear Groove Depth [PDF]
Patellar luxation is a common orthopedic condition in cats, and evaluation of trochlear groove depth is important to determine the need for trochleoplasty during surgical planning. This study compared radiography, ultrasonography, and computed tomography
Guilherme Pfeiffer da Silva +6 more
doaj +2 more sources
Computed Tomography and Scanning Electron Microscopy Analysis of a Friction Stir Welded Al-Cu Joint [PDF]
The study aimed touse3D computed tomography (CT) to analyse a joint between two dissimilar materials produced by friction stir welding (FSW). As the materials joined, i.e., aluminum and copper, differ in properties (e.g., density and melting point), the ...
Wojciech P. Depczyński +2 more
doaj +1 more source
Comparison of Diagnostic Accuracy of Radiation Dose-Equivalent Radiography, Multidetector Computed Tomography and Cone Beam Computed Tomography for Fractures of Adult Cadaveric Wrists. [PDF]
To compare the diagnostic accuracy of radiography, to radiography equivalent dose multidetector computed tomography (RED-MDCT) and to radiography equivalent dose cone beam computed tomography (RED-CBCT) for wrist fractures.As study subjects we obtained ...
Jakob Neubauer +9 more
doaj +1 more source
X-ray Digital Radiography and Computed Tomography
In recent years, X-ray imaging has rapidly grown and spread beyond the medical field; today, it plays a key role in diverse research areas [...]
Maria Pia Morigi, Fauzia Albertin
doaj +1 more source
Background: Routine pelvic radiograph examination commonly performed in diagnostic radiology services is a pelvic examination of anteroposterior projection (AP).
Intan Cahya +4 more
doaj +1 more source
In this work, the pigments and ground layers of the Saint John the Evangelist painting were analyzed using the techniques of computed radiography, X-ray fluorescence (XRF), and micro-Raman spectroscopy.
Francis Anna Cardoso Reis de Almeida Sanches +8 more
doaj +1 more source
Background Errors in radiographic image annotation by radiographers could potentially lead to misdiagnoses by radiologists and wrong side surgery by surgeons. Such medical negligence has dire medico-legal consequences.
Thomas Adejoh +5 more
doaj +1 more source