Feasibility study of skin dosimetry with TLD sheets for measuring the effect of 3D printed bolus in radiotherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract The thermoluminescence dosimeter (TLD) sheet is a measurement device coated with manganese‐doped LiB3O5 in sheet form. The sheet is 0.2‐mm thick and flexible. Hence, it can fit and be installed on irregular surfaces. The current study aimed to evaluate the feasibility of measuring patient surface doses during radiation therapy using TLD sheets.
Yuya Miyasaka   +8 more
wiley   +1 more source

Automatic skin flash optimization in breast and chestwall VMAT with static angle modulated ports: Effect of HU and flash margin size on plan quality and robustness

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Skin flash is typically added to breast and chestwall plans to ensure robust target coverage in the presence of respiratory motion, anatomic changes, and small setup uncertainties. Adding skin flash in volumetric modulated arc therapy (VMAT) plans is an iterative and manual process.
Emily Hubley   +6 more
wiley   +1 more source

Boosting projective methods for quantum process and detector tomography [PDF]

open access: yesarXiv
We introduce two methods for quantum process and detector tomography. In the quantum process tomography method, we develop an analytical procedure for projecting the linear inversion estimation of a quantum channel onto the set of completely positive trace-preserving matrices.
arxiv  

In vivo quantitation of regional myocardial blood flow by positron-emission computed tomography. [PDF]

open access: bronze, 1981
Gerald Wisenberg   +8 more
openalex   +1 more source

Assessing HyperSight iterative CBCT for dose calculation in online adaptive radiotherapy for pelvis and breast patients compared to synthetic CT

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose/objectives Recent technological advancements have increased efficiency for clinical deliverability of online‐adaptive‐radiotherapy (oART). Previous cone‐beam‐computed‐tomography (CBCT) generations lacked the ability to provide reliable Hounsfield‐units (HU), thus requiring oART workflows to rely on synthetic‐CT (sCT) images derived ...
Jingwei Duan   +7 more
wiley   +1 more source

Quantitative Fiber Orientation Analysis of Carbon Fiber Sheet Molding Compounds using Polarization Imaging and X-Ray Computed Tomography [PDF]

open access: yesarXiv
For the quality inspection of carbon fiber sheet molding compounds, polarization imaging is a promising alternative to more established methods like computed tomography, since it is cheaper, faster, and provides a larger field-of-view. For uni- and bidirectional carbon fiber reinforced composite materials, machine vision cameras with on-chip polarized ...
arxiv  

Detection and quantitation of myocardial infarction in vivo using transmission computed tomography. [PDF]

open access: bronze, 1981
P.W. Doherty   +5 more
openalex   +1 more source

Evaluating the use of diagnostic CT with flattening filter free beams for palliative radiotherapy: Dosimetric impact of scanner calibration variability

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Palliative radiotherapy comprises a significant portion of the radiation treatment workload. Volumetric‐modulated arc therapy (VMAT) improves dose conformity and, in conjunction with flattening filter free (FFF) delivery, can decrease treatment times, both of which are desirable in a population with a high probability of retreatment ...
Madeleine L. Van de Kleut   +2 more
wiley   +1 more source