Results 1 to 10 of about 2,534 (99)

Comparative Evaluation of Condylar Guidance Angles Measured Using Arcon and Non-Arcon Articulators and Panoramic Radiographs—A Systematic Review and Meta-Analysis [PDF]

open access: yesLife, 2023
The condylar guidance value (CGV) measurement constitutes an important part of a holistic prosthodontic treatment plan, with horizontal CGVs (HCGVs) and lateral CGVs (LCGVs) being two of the most prominently recognized.
Mohamed Sghaireen, Deepti Shrivastava
exaly   +4 more sources

Proposing a revised Hanau's formula for determining lateral condylar guidance: A comparative study [PDF]

open access: yesJournal of Oral Biology and Craniofacial Research
Background: Inaccurate lateral condylar guidance (LCG) recordings lead to occlusal interferences, increasing patient discomfort and chair-side time. This study aimed to assess and compare the accuracy of LCG calculated using Hanau's formula and right and
Prashant Jadhav   +2 more
exaly   +4 more sources

Effect of a novel rotation coordinating device on registered horizontal condylar guidance of nonarcon semi-adjustable articulators [PDF]

open access: yesDental Research Journal, 2023
Background: Horizontal condylar guidance (HCG) is registered by protrusive interocclusal records but in nonarcon articulators, these records can affect the accuracy.
Farbod Manshaee   +3 more
doaj   +2 more sources

Comparative evaluation of condylar guidance obtained by three different interocclusal recording materials in a semi-adjustable articulator and digital panoramic radiographic images in dentate patients: An in vivo study [PDF]

open access: yesThe Journal of Indian Prosthodontic Society, 2021
Aim: The Aim of the study was to evaluate the reproducibility of condylar inclination values obtained using three different interocclusal recording materials in Hanau Wide-Vue semi-adjustable articulator and to compare those values of condylar ...
S R Keerthana   +4 more
doaj   +2 more sources

Evaluation of horizontal condylar guidance on a fully adjustable articulator at varying protrusive distances: An in vivo study [PDF]

open access: yesThe Journal of Indian Prosthodontic Society
Aim: This study aimed to assess the accuracy of HCG values obtained with records at various protrusive distances on a fully adjustable articulator. Settings and Design: Pantographs are used for condylar settings on a fully adjustable articulator but are ...
Jayant N. Palaskar   +3 more
doaj   +2 more sources

A comparative evaluation of lateral condylar guidance by clinical and radiographic methods – Hanau's formula revisited [PDF]

open access: yesJournal of Pharmacy and Bioallied Sciences, 2021
Background: Various clinical methods for recording the condylar guidance (CG) are the intraoral check bite method, graphic tracings, and functional recordings.
Kanagesan Praveena   +5 more
doaj   +2 more sources

Complicated Relationships between Anterior and Condylar Guidance and Their Clinical Implications—Comparison by Cone Beam Computed Tomography and Electronic Axiography—An Observational Cohort Cross-Sectional Study [PDF]

open access: yesLife, 2023
A complex prosthodontic treatment is believed to be more successful when the condylar path is replicated using the articulator. However, there is an ongoing major disagreement between the researchers as the exact relationship between the posterior and ...
Łukasz Lassmann   +3 more
doaj   +2 more sources

An in vitro study to evaluate the accuracy of orthopantomograph as an aid to determine condylar guidance [PDF]

open access: yesThe Journal of Indian Prosthodontic Society, 2018
Purpose: The study was conducted to evaluate the accuracy of orthopantomograph (OPG) as an aid to determine condylar guidance. Methodology: The condylar guidance was measured using the impressions of glenoid fossae and radiographs (OPG) on thirty dried ...
Sukhjit Kaur, Kusum Datta
doaj   +2 more sources

Articulator Zeroing on Condylar Guidance Values: A Comparative Study of Hanau and Artex Systems [version 1; peer review: 2 approved] [PDF]

open access: yesF1000Research
Purpose Accurate replication of mandibular movements is essential for successful prosthodontic rehabilitation. Semi-adjustable articulators are commonly used for this purpose, and zeroing is a preparatory step intended to standardize articulator settings.
Mallikarjuna Ragher   +6 more
doaj   +2 more sources

Rotation coordinating device for improving condylar guidance settings of nonarcon articulators: Part 1 [PDF]

open access: yesDental Research Journal, 2018
Background: Setting of condylar inclination is inaccurate in nonarcon articulators because of alteration of the angle between the upper member and condylar track.
Farbod Manshaee, Hadi Shakerin
doaj   +2 more sources

Home - About - Disclaimer - Privacy