Results 131 to 140 of about 588 (176)
Some of the next articles are maybe not open access.
Cone penetrometer and liquid limit
Géotechnique, 1982The suitability of a simple expression, containing the specific gravity of soil particles, relating the plasticity index and compression index for soils at their plastic and liquid limits is tested by comparing predicted values with measured values of the compression index.
openaire +2 more sources
2010
A static cone penetrometer was modified to incorporate a small diameter triaxial geophone package. This instrument was evaluated by obtaining downhole shear wave velocity profiles at selected research sites on the Fraser River Delta near Vancouver B.C. for the purpose of determining in-situ dynamic shear moduli.
openaire +1 more source
A static cone penetrometer was modified to incorporate a small diameter triaxial geophone package. This instrument was evaluated by obtaining downhole shear wave velocity profiles at selected research sites on the Fraser River Delta near Vancouver B.C. for the purpose of determining in-situ dynamic shear moduli.
openaire +1 more source
Site investigation with static cone penetrometer
International Journal of Rock Mechanics and Mining Sciences & Geomechanics Abstracts, 1976A geotechnical investigation of a 100-acre (404,700 sq m) site adjacent to the Savannah River in Augusta, Ga., is described. Extensive and economical use was made of the static cone penetrometer with friction jacket in establishing subsurface conditions and estimating geotechnical engineering properties of micaceous sands and organic clays for design ...
Robert Alperstein, Samuel A. Leifer
openaire +2 more sources
Cone Penetrometer Applications A Review
Transactions of the ASAE, 1987ABSTRACT THIS report provides a history of cone penetrometers, a description of the various types, an explanation of the factors affecting the penetration resistance, and a discussion of possible applications of cone penetrometers.
openaire +1 more source
A Multisleeve Friction Attachment for the Cone Penetrometer
Geotechnical Testing Journal, 2002Abstract Accurate knowledge of the strength of soil-geomaterial interfaces is becoming of increasing importance in geotechnical engineering. Systems whose performance is heavily dependent on soil-geomaterial interfaces include deep foundations, synthetic impervious liners, trenchless technologies, and an assortment of earth retaining ...
JT DeJong, J David Frost
openaire +1 more source
Development and calibration of radio-isotope cone penetrometers
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2005Radio-Isotope cone penetrometers (RI-cones) are developed to measure the basic soil properties like water content and soil density under in situ conditions in real time along with other parameters such as soil strength and hydrogeologic conditions of subsurface soils.
openaire +2 more sources
Electronically‐controlled, portable, cone penetrometer
Communications in Soil Science and Plant Analysis, 1998Abstract An electronically‐controlled, portable, cone penetrometer was designed, built, and tested. The penetrometer was driven electrically through a linear actuator. Cone position was sensed by a 10‐turn potentiometer, and force was sensed with an electronic load cell.
N. B. Christensen +3 more
openaire +1 more source
Validation of the automatic dynamic cone penetrometer
2022The U.S. military requires a rapid means of measuring subsurface soil strength for construction and repair of expeditionary pavement surfaces. Traditionally, a dynamic cone penetrometer (DCP) has served this purpose, providing strength with depth profiles in natural and prepared pavement surfaces.
Ernest Berney +2 more
openaire +1 more source
A Cone Penetrometer System for Measuring Cone Index and Stress Relaxation
Transactions of the ASAE, 1989ABSTRACT Aportable computer controlled cone penetrometer was designed for making cone index and relaxed cone index measurements. The new penetrometer is DC powered and was interfaced to an IBM personal computer. Software was used for controlling the penetrometer motor speed (penetration rate), and sampling cone depth, cone index and stress relaxation ...
null E. W. Tollner, null W. Simonton
openaire +1 more source
The calibration of a friction cone penetrometer in sand
2022This thesis was scanned from the print manuscript for digital preservation and is copyright the author. Researchers can access this thesis by asking their local university, institution or public library to make a request on their behalf. Monash staff and postgraduate students can use the link in the References field.
openaire +1 more source

