Results 61 to 70 of about 49,672 (273)

Carboxylic‐Acid Functionalized Multiwalled Carbon Nanotube‐Alkane‐Based Resistive Temperature Sensor for Cold Chain Applications

open access: yesAdvanced Engineering Materials, EarlyView.
This study presents a reversible temperature sensor with high switching ratio, ∼103. The device is fabricated using PET‐ITO and carbon nanotube dispersions in alkane. Considering its application in cold chain logistics, a proof‐of‐concept with LED is showcased. Thus, a temperature drop below the threshold temperature (crystallization temperature of the
Sunil Kumar Behera   +8 more
wiley   +1 more source

A Compact Spin‐Coated Graphene UWB Antenna for Breast Tumor Detection

open access: yesAdvanced Engineering Materials, EarlyView.
A compact, spin‐coated graphene ultra‐wideband patch antenna designed for breast tumor detection, capable of distinguishing between malignant and benign tumors. This innovative antenna can serve as an effective initial screening tool, particularly in resource‐limited settings such as rural areas, where access to advanced medical equipment like MRI and ...
Raja Rashidul Hasan   +9 more
wiley   +1 more source

Raman Spectroscopic Identification of Oxide Phases in a Corroded MgO–Steel Composite Anode Used in Aluminum Molten Salt Electrolysis

open access: yesAdvanced Engineering Materials, EarlyView.
Micro‐Raman spectroscopy is applied to characterize corrosion products in a recycled‐based MgO–316L steel composite anode after molten salt electrolysis. A depth‐dependent Fe–O/Fe–Al–O layer sequence of magnetite, hercynite, and an Al‐doped magnetite transition zone is identified.
Felix Drechsler   +9 more
wiley   +1 more source

Interaction of MgO Recyclate‐Based Cermet Anode With KF‐AlF3‐Al2O3 at 800°C During Laboratory Scale Aluminum Molten Salt Electrolysis

open access: yesAdvanced Engineering Materials, EarlyView.
A carbon‐free, as‐sintered MgO–steel cermet anode, fabricated via cold isostatic pressing using MgO–C refractory recyclate, was evaluated under laboratory‐scale K‐cryolite electrolysis at 800°C. Operation at this reduced temperature, combined with the electrolyte's limited electrical conductivity, led to an increase in cell voltage.
Farhan Hossain   +7 more
wiley   +1 more source

NanoMOF‐Based Multilevel Anti‐Counterfeiting by a Combination of Visible and Invisible Photoluminescence and Conductivity

open access: yesAdvanced Functional Materials, EarlyView.
This study presents novel anti‐counterfeiting tags with multilevel security features that utilize additional disguise features. They combine luminescent nanosized Ln‐MOFs with conductive polymers to multifunctional mixed‐matrix membranes and powder composites. The materials exhibit visible/NIR emission and matrix‐based conductivity even as black bodies.
Moritz Maxeiner   +9 more
wiley   +1 more source

Near‐Infrared Emitting Lanthanide Catecholate Giant Single Crystals – Morphology Control and Photon Down‐Conversion

open access: yesAdvanced Functional Materials, EarlyView.
Controlled syntheses of lanthanide coordination polymers based on the dihydroxybenzoquinone (DHBQ) organic linker afforded large single crystals of Ln‐DHBQ CPs (Ln = Yb, Nd). A novel structural variant of Yb‐DHBQ is identified by means of single crystal diffraction analysis.
Marina I. Schönherr   +7 more
wiley   +1 more source

Raman Microscopy at the Organic–Inorganic Interfaces in Human Calcified Aortic Valves Shows the Co‐Existence of Whitlockite Crystals and Carbonated Hydroxyapatite‐Mineralized Collagen Fibrils

open access: yesAdvanced Functional Materials, EarlyView.
This study advances our understanding of aortic valve stenosis by capturing spatially resolved chemical and structural changes at the nanoscale. The findings highlight the potential of combined Raman and electron microscopy for understanding calcification mechanisms across diverse tissue types.
Robin H. M. Van der Meijden   +11 more
wiley   +1 more source

Raman confocal microscopy atlas of human tooth

open access: yesArchives of Oral Biology
Dental histology is a field that has been studied since the early 19th century. Most of the techniques used have been based on white-light microscopy or histological staining, or more recently immunohistochemical staining. With the advent of lasers coupled to confocal microscopy, Raman spectra can be measured in large numbers to create a detailed ...
Collart-Dutilleul, P.-Y.   +8 more
openaire   +3 more sources

Confocal Raman microspectroscopy for spatially resolved tissue characterisation of disease‐linked spectra‐pathological signatures

open access: yesClinical and Translational Medicine
Raman spectroscopy is a versatile analytical technique for highly specific molecular characterisation of cells, biofluids and tissues. Confocal Raman microspectroscopy combines optical microscopy with Raman spectroscopy to spatially resolve biochemical ...
Nektarios A. Valous   +2 more
doaj   +1 more source

Local Study of Lithiation and Degradation Paths in LiMn2O4 Battery Cathodes: Confocal Raman Microscopy Approach

open access: yesBatteries, 2018
Lithium manganese-based cathodes are widely used in rechargeable batteries due to their low cost, safety, and ecological stability. On the other hand, fast capacity fade occurs in LiMn2O4 mainly because of the induced manganese dissolution and formation ...
Boris Slautin   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy