A high‐density wearable body‐surface potential mapping array reveals how gravity reshapes cardiac conduction in real time. By resolving spatiotemporal delay patterns invisible to conventional ECG, the platform uncovers posture‐dependent electrophysiological adaptations across the thorax.
Ruben Ruiz‐Mateos Serrano +4 more
wiley +1 more source
Bifurcation analysis and analytical traveling wave solutions of a sasa-satsuma equation involving beta, M-truncated and conformable derivatives using the EGREM method. [PDF]
Munir F +5 more
europepmc +1 more source
Graphene‐Based Wearable Textile Triboelectric Nanogenerators and Biomechanical Sensors
This study presents a wearable textile‐based triboelectric nanogenerator (T‐TENG) using sprayed graphene enhanced with a PVA adhesion layer. The graphene‐based electrode demonstrates high electrical conductivity and robustness to multiple bends. The fabricated T‐TENG provides stable and efficient output, with strong responsiveness to biomotion.
Hongyang Dang +4 more
wiley +1 more source
Periodic solutions for conformable type non-instantaneous impulsive differential equations
Yuanlin Ding, Jinrong Wang
doaj
Conformable Device for Independent Measurements of Mucosal and Vascular Barriers in a Complex In Vitro Intestinal Model. [PDF]
Wheeler AE +7 more
europepmc +1 more source
Flexible piezopolymer ultrasound transducers are engineered by tailoring the electrode–piezopolymer interface using metallic, flake‐based, and porous graphene electrodes. Laser‐induced graphene's porous structure enables polymer infiltration, strengthening interfacial coupling and enhancing piezoelectric response and acoustic output.
Spencer Hagen +3 more
wiley +1 more source
Superintegrated conformable organic transistors based on a universal microlithographic strategy. [PDF]
Ni Y +9 more
europepmc +1 more source
Ultra‐Flexible Dual‐Band Organic Photodetectors for Visible and Near‐Infrared Sensing
An ultra‐flexible dual‐band organic photodetector with a total thickness of 5.6 µm for bio‐sensing is developed. It selectively detects visible and near‐infrared light with high sensitivity by switching the voltage. Peripheral oxygen saturation (SpO2) measurement is demonstrated using the device attached to a finger under a single light source by ...
Sachi Awakura +6 more
wiley +1 more source
Exploring complex dynamics in nonlinear Riemann wave models using fractional calculus-based expansion. [PDF]
Mumtaz A, Masood K, Shakeel M, Shah NA.
europepmc +1 more source
This article presents dielectric elastomer switch (DES) materials, based on composite thin films. Alignment of graphite flakes due to their physical confinement within the thin films lead to much stronger piezoresistive responses than bulk composites, while their durability exceeds that of conventional liquid‐based DES materials.
Lingyu Liu +3 more
wiley +1 more source

