Results 151 to 160 of about 7,580,136 (353)
Supply Fan Control for Constant Air Volume Air Handling Units [PDF]
Since terminal boxes do not have a modulation damper in constant volume (CV) air handling unit (AHU) systems, zone reheat coils have to be modulated to maintain the space temperature with constant supply airflow. This conventional control sequence causes
Liu, M., Cho, Y., Wang, G.
core
This study explored how effective nickel aluminide coatings are obtained in providing oxidation resistance applied to the Inconel 738 alloy, modeling with diffusion models. In the present study, kinetics and thermal behavior of the Inconel 738 alloy were studied by the low‐temperature thermoreactive aluminizing process, which was carried out at 625°C ...
Gozde Celebi Efe +4 more
wiley +1 more source
Constant-volume control of canals
Presented at Irrigation and water resources in the 1990's: proceedings from the 1992 national conference held on October 5-7, 1992 in Phoenix, Arizona.The Saint-Venant equations of open-channel flow were linearized using the Taylor series expansion ...
Reddy, J. Mohan, author +1 more
core
This study demonstrates an efficient recycling route for out‐of‐spec AlSi10Mg atomized powders through compaction and arc remelting followed by suction casting. By correlating compaction load, cooling rate, and resulting microstructure, we show that intermediate pressures (50–80 kN) and rapid cooling refine dendrites, reduce porosity, and enhance ...
Mila Christy de Oliveira +4 more
wiley +1 more source
Comparison of spray combustion for Jet-A and diesel in a constant volume chamber
This work investigates the effect of ambient conditions on jet-A spray combustion in an optical constant volume combustion chamber. Based on the data of jet-A and diesel fuel data obtained from previous experiments, a comparison between jet-A and diesel ...
Roberts, William L. +2 more
core
Buckling loads of columns of regular polygon cross-section with constant volume and clamped ends
A numerical method is developed for calculating the buckling loads of tapered columns of regular polygon cross-section with constant volume and both clamped ends. The linear, parabolic and sinusoidal tapers are considered in numerical examples. From the
Byoung Koo Lee, Sang Jin Oh, Guangfan Li
doaj
Levocetirizine, an antihistamine, has been analyzed in relation to temperature by volumetric, acoustic, and spectroscopic methods to investigate its interaction with glucose, the predominant carbohydrate.
Navya Grover +4 more
doaj +1 more source
A Workflow to Accelerate Microstructure‐Sensitive Fatigue Life Predictions
This study introduces a workflow to accelerate predictions of microstructure‐sensitive fatigue life. Results from frameworks with varying levels of simplification are benchmarked against published reference results. The analysis reveals a trade‐off between accuracy and model complexity, offering researchers a practical guide for selecting the optimal ...
Luca Loiodice +2 more
wiley +1 more source
Constant volume CBM reservoirs: An important principle
Much research and many field trials have shown that the permeability of coal seams varies inversely with the effective stress acting on coal. It was later theorized by Gray (1992) that desorption-induced matrix shrinkage may counter-act the effect of ...
Rudolph, Victor +2 more
core
The cosmological constant and volume-preserving diffeomorphism invariants
31 pgs, 3 figs (seperate file), Latex, CTP ...
openaire +2 more sources

