Results 111 to 120 of about 9,826,001 (249)

Flexible wearable electronics for cardiovascular monitoring from surface signals to deep physiological insights

open access: yesFlexMat, EarlyView.
This review organizes flexible wearable electronics for cardiovascular monitoring into four interconnected information layers: surface electrophysiology, hemodynamic sensing, vascular imaging, and biofluid biomarker analysis. This framework clarifies how electrical rhythm, vascular loading, structural and flow‐related features, and biochemical states ...
Qiao Chen   +5 more
wiley   +1 more source

Respuesta ortostática de la tensión arterial de pacientes con enfermedad de Parkinson inicial

open access: yes, 2013
Objetivo: Evaluar la respuesta ortostática de la tensión arterial de forma no invasiva en pacientes con enfermedad de Parkinson inicial leve a moderada atendidos en el Instituto Nacional de Neurología y Neurocirugía.
Cervantes-Arriaga,Amin   +3 more
core  

Triboelectric nanogenerators for vehicle intelligent cockpits

open access: yesFlexMat, EarlyView.
Converting mechanical stimuli from drivers and vehicle motion into electrical signals, triboelectric nanogenerators provide promising interfaces toward passive, flexible, distributed and intelligent sensing for next‐generation automotive cockpits to support three core functional dimensions: driver state monitoring, vehicle state monitoring, and human ...
Haiqiu Tan   +9 more
wiley   +1 more source

A flexible dual‐gate thin‐film transistor‐based tactile sensor array with polarity‐aware encoding for neuromorphic recognition

open access: yesFlexMat, EarlyView.
A flexible piezoelectric tactile sensor array is developed by integrating polyvinylidene fluoride sensing elements with dual‐gate indium‐tin‐zinc oxide thin‐film transistor‐based pixel amplifiers. Direct coupling to the high‐impedance gate minimizes signal loss, enabling twofold voltage amplification and an extended effective relaxation time of ∼4.86 s
Tengteng Lei   +4 more
wiley   +1 more source

Hipertensión arterial en el escolar con antecedente de macrosomía o alto peso al nacer Blood hypertension in the schoolchild with history of macrosomy or high birth weight

open access: yesRevista Cubana de Investigaciones Biomédicas, 2009
Poco se ha investigado en relación con el alto peso al nacer y los factores de riesgo aterosclerótico. Los hechos precursores de enfermedades como las cardiovasculares, específicamente la hipertensión arterial, se establecen desde la infancia, pero sus ...
Nuris Rodríguez Vargas   +4 more
doaj  

Progress in the Role of Mast Cells and Biomolecular Signals in the Mechanism of Postoperative Ileus: From Cellular Activation to Exploration of the Brain–Gut Axis

open access: yesGut Medicine, EarlyView.
ABSTRACT Postoperative ileus (POI) is a frequent complication after surgical procedures, predominantly manifesting as aberrant gastrointestinal motility, which markedly extends the duration of postoperative recovery for patients. The clinical duration of POI is typically modulated by intricate inflammatory cascades, with mast cells assuming a critical ...
Tian‐le Zhang   +4 more
wiley   +1 more source

¿Disminuir la tensión arterial protege la memoria?

open access: yes
La pregunta que planteamos es la siguiente, ¿puede el control intensivo de la tensión arterial desde Atención Primaria disminuir el riesgo de demencia en nuestra población? La evidencia disponible sugiere que sí.
Hernández Montiel, A.S.D.   +2 more
core  

Vivenciando a rede de apoio social de pessoas com hipertensão arterial de uma comunidade na Amazônia [PDF]

open access: yes, 2012
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Enfermagem, Florianópolis, 2010O apoio social é um elemento importante que contribui para a proteção e melhora da saúde das pessoas; e a ...
Tavares, Roseneide dos Santos
core  

The Dead Donor Rule and Normothermic Regional Perfusion

open access: yesHastings Center Report, EarlyView.
Abstract Normothermic regional perfusion (NRP) can be used after the circulatory determination of death to prevent or minimize organ damage before the donor's organs are retrieved. It involves restarting circulation within the donor's body to reperfuse abdominal and thoracic organs while occluding the arteries that supply oxygenated blood to the brain ...
Andrew McGee   +3 more
wiley   +1 more source

Spontaneous hemoperitoneum in a 29‐week pregnancy with a history of endometriosis: A case report and review of the literature

open access: yesInternational Journal of Gynecology &Obstetrics, Volume 169, Issue 1, Page 31-37, April 2025.
Abstract Spontaneous hemoperitoneum in pregnancy (SHIP) is defined as sudden, nontraumatic intraperitoneal bleeding that occurs during pregnancy or up to 42 days postpartum. The incidence ranges between 4 and 4.9 per 100 000 births. Although seen rarely, it is associated with perinatal morbidity and mortality due to maternal hemodynamic instability ...
Shamsi Mehdiyev   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy