Results 131 to 140 of about 592,843 (298)
The fused filament‐fabricated MAR‐M247 alloy without hot isostatic pressing shows the lowest porosity of 4%. Heat treatment at 1220 °C produces coarse precipitates and carbides. Specimens heat‐treated at 1220 °C exhibit higher tensile strength (683 MPa) and elongation (10%) at room temperature.
Haneen Daoud+7 more
wiley +1 more source
LII. On the law of cooling, and its bearing on certain equations in the analytical theory of heat [PDF]
Charles H. Lees
openalex +1 more source
This work reveals the phase composition and quantitative morphology analysis of precipitation‐hardened Fe32Cu12Ni11Ti16Al29 complex‐concentrated alloy. The precipitates are shown to have a high coherency. Morphology transition between sphere, cuboidal, and elongated morphology is observed. Finally, the overaging behavior is captured using microhardness.
Rostyslav Nizinkovskyi+4 more
wiley +1 more source
Heat Transmission for Rapid Cooling of High Temperature Bodies
Yuzo NAKAGAWA, Tetsuo Yoshida
openalex +2 more sources
Experiments for reinforcing the diffusion bonding plane by the oxide dispersion strengthening effect are presented. Small ceramic particles (0.5 and 50 μm, respectively) are incorporated. Furthermore, ceramic particles help to penetrate stable passivation layers, enabling atomic diffusion across bonding planes. Since a ceramic–metallic interface cannot
Thomas Gietzelt+4 more
wiley +1 more source
The effect of cooling power of the atmosphere on body metabolism
J. A. Campbell+2 more
openalex +2 more sources
In the present study, metastable CrMnNi steels with varying chemical compositions and a concomitantly altered stacking fault energy are processed via directed energy deposition and afterwards tested via tensile tests at different temperatures. The present study shows the influence of the manufacturing process on the elemental deformation mechanisms for
Julia Richter+8 more
wiley +1 more source
A simulative evaluation of triply periodic minimal surface (TPMS) structures for an elastocaloric application under compressive load is performed. For the evaluation of the structure's performance, surface/volume ratio, generated heat and invested mechanical work are taken into account and are compared to a tube as a reference specimen.
Michael Fries+3 more
wiley +1 more source
Subjective and objective quality of sleep with radiant or convection cooling systems: a randomized, cross-over trial. [PDF]
Park I+12 more
europepmc +1 more source