Results 281 to 290 of about 9,293,019 (395)

Influence of artificial tears on corneal parameter measurement using three different devices: Keratometry and Scheimpflug technology, a randomized trial

open access: yesActa Ophthalmologica, EarlyView.
Abstract Purpose To evaluate the effect of artificial tear (AT) application on the repeatability of corneal parameters with three different devices. Methods In this prospective, randomized clinical trial, 145 patients were measured with one of three devices in the Department of Ophthalmology, Goethe University, Frankfurt, Germany.
Titus Schug   +3 more
wiley   +1 more source

Cover and Masterhead

open access: yesVision Pan-America, 2013
Paulo E.C. Dantas
doaj   +1 more source

Comparison of Postoperative Outcomes in 71 Patients Undergoing Cataract Surgery at a Single Center with and Without Preoperative Keratostill Moisturizing Eye Drops. [PDF]

open access: yesJ Clin Med
Miklaszewski P   +7 more
europepmc   +1 more source

Combined Vitrectomy and Clear Corneal Phacoemulsification in Patients with Vitreoretinal Diseases

open access: hybrid, 2015
Orhan Ates Ibrahim Kocer   +2 more
openalex   +1 more source

Considerations on the Haigis formula: Are better outcomes possible with tuning?

open access: yesActa Ophthalmologica, EarlyView.
Abstract Purpose To design a vergence‐based lens power formula based on the classical Haigis formula for better outcomes while retaining the original formula architecture. Methods Four new formula variants (A–D) incorporating a sum of segments correction for axial length, harmonic mean of corneal radii instead of arithmetic mean (all variants), and ...
Achim Langenbucher   +5 more
wiley   +1 more source

Digital transformation of care for keratoconus patients: ML modeling structural outcomes of corneal collagen cross-linking. [PDF]

open access: yesFront Med (Lausanne)
Statsenko Y   +11 more
europepmc   +1 more source

Molecular and cellular mechanisms underlying gyrate atrophy: Why is the retina primarily affected?

open access: yesActa Ophthalmologica, EarlyView.
Abstract Gyrate atrophy of the choroid and retina (GACR; OMIM #258870) is a rare early‐onset autosomal recessive disorder, caused by bi‐allelic pathogenic variants in the gene coding for ornithine aminotransferase (OAT) resulting in hyperornithinaemia.
Mark J. N. Buijs   +12 more
wiley   +1 more source

Preservatives in artificial tears: Assessing impact on dry eye symptoms

open access: yesActa Ophthalmologica, EarlyView.
Abstract Purpose To examine the association between the presence of dry eye disease (DED) symptoms when using BAK‐preserved artificial tears (AT) compared to preservative‐free AT. Methods In this cross‐sectional study, we used data collected as part of Project ‘Finding Ophthalmic Risk and Evaluating the Value of Eye exams and their predictive ...
Astrid Dissing Sjö   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy