Results 71 to 80 of about 37,507 (244)

Mid‐Infrared Integrated Photonics: Material Platforms and Emerging Applications

open access: yesLaser &Photonics Reviews, EarlyView.
Mid‐infrared (MIR) integrated photonics enables advanced chemical and biological sensing through the unique absorption features of molecules in the 2–20 µm range. This review highlights recent material advances such as chalcogenide glasses, silicon, and graphene and explores MIR applications in environmental monitoring, medical diagnostics ...
Muhammad Ali Butt   +2 more
wiley   +1 more source

Informed consent in refractive surgery: in-person vs telemedicine approach. [PDF]

open access: yes, 2018
Purpose:The aim of this study was to compare the quality of consent process in refractive surgery between patients who had a preoperative consent discussion with the surgeon using a telemedicine approach and those who had a face-to-face discussion ...
Hannan, Stephen J   +4 more
core   +1 more source

Dynamic Retinal Pathology in Glaucoma Progression Revealed by High‐Resolution Functional Imaging in Vivo

open access: yesLaser &Photonics Reviews, EarlyView.
In this work, we investigated the dynamic retinal pathology of glaucoma from onset to late stages through longitudinal in vivo high‐resolution imaging in a silicone oil‐induced ocular hypertension (SOHU) glaucoma mouse model. We developed an optimized adaptive optics two‐photon excitation fluorescence microscopy (AO‐TPEFM) technique for morphological ...
Yiming Fu   +6 more
wiley   +1 more source

Cataract Surgery in Eyes with Low Corneal Astigmatism: Implantation of the Acrysof IQ Toric SN6AT2 Intraocular Lens

open access: yesJournal of Ophthalmic & Vision Research, 2014
Purpose: To assess the refractive and visual outcomes following cataract surgery and implantation of the AcrySof IQ Toric SN6AT2 intraolcular lens (IOL) (Alcon Laboratories, Inc., Fort Worth, TX, USA) in patients with low corneal astigmatism.
Jaskirat S Aujla   +3 more
doaj   +1 more source

Scleral contact lenses for visual rehabilitation in keratoconus and irregular astigmatism after refractive surgery [PDF]

open access: yes, 2009
This study aims to report our experience of using fluid-ventilated, gas-permeable scleral contact lenses (SCLs) for visual rehabilitation of patients with keratoconus and irregular astigmatism after refractive surgery.
Lo, Hua-Lin   +2 more
core   +1 more source

A review of angle kappa and multifocal intraocular lenses and their effect on visual outcomes

open access: yesActa Ophthalmologica, EarlyView.
Abstract Although most patients are satisfied with their vision after multifocal intraocular lens (IOL) implantation, dissatisfaction has been reported for various reasons, including poor visual outcomes and visual disturbances. Many published reports hypothesise that preoperative angle kappa may be an associated factor in patient dissatisfaction ...
Thomas Kohnen   +2 more
wiley   +1 more source

Corneal Refractive Surgery in Patients with a History of Herpes Simplex Keratitis: A Narrative Review

open access: yesClinical Ophthalmology, 2020
Majid Moshirfar,1– 3 Dallin C Milner,4 Preston A Baker,5 Shannon E McCabe,1 Yasmyne C Ronquillo,1 Phillip C Hoopes1 1Hoopes Vision Research Center, Hoopes Vision, Draper, UT, USA; 2John A.
Moshirfar M   +5 more
doaj  

Refractive Accuracy of Barrett True-K vs Intraoperative Aberrometry for IOL Power Calculation in Post-Corneal Refractive Surgery Eyes

open access: yesClinical Ophthalmology, 2021
Larissa Gouvea,1,2 Kareem Sioufi,3 Colin E Brown,3 George Waring IV,4 Wallace Chamon,2 Karolinne Maia Rocha3 1Department of Ophthalmology and Visual Sciences, University of Toronto, Toronto, ON, Canada; 2Department of Ophthalmology and Visual Sciences ...
Gouvea L   +5 more
doaj  

A two‐step formula constant optimization strategy for minimal standard deviation and zero mean prediction error in IOL power calculation

open access: yesActa Ophthalmologica, EarlyView.
Abstract Purpose To investigate the precision and accuracy performance of a two‐step approach for optimizing lens formula constants (FC) with a refractive offset correction (RO) as a second tuning parameter. Methods Using IOLMaster 700 biometric data from 4 datasets (886/613/821/467 eyes treated with the Hoya Vivinex/Johnson&Johnson ZCB00/Alcon SA60AT ...
Achim Langenbucher   +5 more
wiley   +1 more source

Unintended changes in ocular biometric parameters during a 6-month follow-up period after FS-LASIK and SMILE

open access: yesEye and Vision, 2021
Background Corneal refractive surgery has become reliable for correcting refractive errors, but it can induce unintended ocular changes that alter refractive outcomes. This study is to evaluate the unintended changes in ocular biometric parameters over a
Junjie Wang   +10 more
doaj   +1 more source

Home - About - Disclaimer - Privacy