Results 11 to 20 of about 36,125 (294)
Applications of corneal topography and tomography: a review [PDF]
AbstractCorneal imaging is essential for diagnosing and management of a wide variety of ocular diseases. Corneal topography is used to characterize the shape of the cornea, specifically, the anterior surface of the cornea. Most corneal topographical systems are based on Placido disc that analyse rings that are reflected off the corneal surface.
Rachel Fan +3 more
openaire +5 more sources
Enhancement of Corneal Visibility in Optical Coherence Tomography Images with Corneal Opacification
To establish and to rank the performance of a corneal adaptive compensation (CAC) algorithm in enhancing corneal images with scars acquired from three commercially available anterior segment optical coherence tomography (ASOCT) devices.Horizontal B-scans of the cornea were acquired from 10 patients using three ASOCT devices (Spectralis, RTVue, and ...
Chung, Cheuk Wang +6 more
openaire +3 more sources
Corneal tomography in osteogenesis imperfecta [PDF]
Osteogenesis Imperfecta (OI) is a rare genetic disorder with musculoskeletal manifestations and some ocular features, such as the presence of blue sclerae, corneal thinning, altered corneal biomechanics, and rare reports of keratoconus (KC). Corneal tomography is essential for KC screening and a BAD_D score over 1,6 and 2,6 is highly sensitive and ...
Barão, R. +7 more
openaire +2 more sources
Purpose: To report the clinical course and compare the utility of Scheimpflug tomography (ST) and anterior segment optical coherence tomography (AS-OCT) for central corneal thickness (CCT) and corneal densitometry (CD) assessment in patients with corneal crystals owing to nephropathic cystinosis.
Leonie Vercauteren +5 more
core +8 more sources
Changes in corneal tomography following corneal refractive therapy discontinuation in a patient with history of long-term use [PDF]
Rebecca R Lian, Ruti Sella
exaly +2 more sources
Taher K Eleiwa,1,2 Mona Abd El-Azim Mohammed,3 Ahmed Sherin M Bayoumy1 1Department of Ophthalmology, Benha University, Benha, Egypt; 2Department of Ophthalmology, Magrabi Eye and Dental Hospital, Qassim, Kingdom of Saudi Arabia; 3Department of ...
Eleiwa TK, Mohammed MAEA, Bayoumy ASM
doaj +2 more sources
Comparison of Corneal Thickness Measurements After Customized Corneal Crosslinking Using High-Resolution Optical Coherence Tomography and Scheimpflug Tomography. [PDF]
PURPOSE The aim of this study was to compare the evolution of corneal pachymetry after customized corneal crosslinking (CXL) between Scheimpflug-based and optical coherence-based corneal tomography (OCT).
Theo G. Seiler +5 more
core +1 more source
Purpose: To investigate the relationship between Ortho-K contact lens design parameters and refractive power change of the eye through a parametric mathematical representation. Methods: The current study utilises fully anonymized records of 249 eyes, 132
Lo-Yu Wu +9 more
doaj +1 more source
Multimodal diagnostics for keratoconus and ectatic corneal diseases: a paradigm shift
Different diagnostic approaches for ectatic corneal diseases (ECD) include screening, diagnosis confirmation, classification of the ECD type, severity staging, prognostic evaluation, and clinical follow-up.
Renato Ambrósio +9 more
doaj +1 more source
Advanced Surface Ablation in Mild (Fruste) Keratoconus: A Case Report
Corneal ectasia is a complication of refractive surgery, and keratoconus is a contraindication to this type of procedure. Surface ablation may be an option for selected cases of mild keratoconus, with patient education being fundamental to this treatment
Louise P. G. Esporcatte +4 more
doaj +1 more source

