Results 181 to 190 of about 12,470 (214)
Decontamination of collards (Brassica oleracea var. acephala L.) using electrolyzed water and corona discharge plasma jet. [PDF]
Seo J, Puligundla P, Mok C.
europepmc +1 more source
Nonthermal plasma approaches for combating implant‐associated infections: A compendious review
Implant‐associated infections pose serious clinical challenges. Non‐thermal plasma (NTP) modifications overcome this bottleneck in distinct ways relative to traditional sterilization methods. Gas‐phase plasmas generate highly energetic species, UV radiation and reactive oxygen/nitrogen species (RONS), which alter the implant surface properties.
A. M. Trimukhe +8 more
wiley +1 more source
Prehabilitation, including preoperative exercise, nutrition optimization, behavioral support, and smoking cessation services, may improve physiological reserve in patients undergoing surgery; however, large administrative and claims‐based real‐world evaluations across diverse procedure types have remained limited.
Meher Angez +6 more
wiley +1 more source
Micro Partial Discharge Characteristics of SF6 Under DC Voltage
ABSTRACT In gas‐insulated high‐voltage direct current (HVDC) devices, micro partial discharges (PD) caused by micro‐protrusions or surface roughness on conductors or enclosures may not cause immediate insulation system failure due to their weak discharge intensity.
Geng Chen +4 more
wiley +1 more source
Resistivity and Tensile Strength of Al–Mg–Si Alloy Wire Conductors
ABSTRACT Aluminium alloy is potentially used for power transmission lines due to its light weight and high strength. The aluminium alloy wire conductors with different Mg and Si contents were studied through electrical resistivity and mechanical properties.
Jing Chen +3 more
wiley +1 more source
ABSTRACT Radio interference (RI) is a critical factor in the design of extra‐high voltage (EHV) transmission lines at high altitudes. To address the insufficient field data of RI on high‐altitude transmission lines, the lack of adequate validation for existing RI prediction methods, and the difficulty in assessing RI levels under various meteorological
Yemao Zhang +6 more
wiley +1 more source
Dynamic Behaviour of Bubbles in Oil Under Electrothermal Ageing
ABSTRACT During long‐term operation of converter transformers, the internal oil–pressboard insulation undergoes irreversible degradation. Partial discharge in the weakened insulation will cause the formation of a large number of bubbles in the insulating oil.
Hongbin Wu +7 more
wiley +1 more source
Research on Ultra‐Wideband Pulse Current Method for DC Partial Discharge Measurement
ABSTRACT The conventional pulse current method is commonly used in AC or DC withstand voltage tests with partial discharge (PD) monitoring. Because of its relatively narrow measurement bandwidth, this method tends to ignore critical information in PD waveforms, making it difficult to eliminate pulse‐type interference under DC voltage conditions, where ...
Kaining Hou +4 more
wiley +1 more source
Study of Positive Corona Discharge of Needle Plate Electrodes in Airflow
ABSTRACT For high‐speed moving objects such as aircraft and wind turbine blades, discharge occurs under strong airflow. Research on lightning attachment characteristics has been extensive, whereas the role of corona discharge in pre‐breakdown streamer development has received less attention.
Lei Lan +6 more
wiley +1 more source
ABSTRACT To address the issue of low detection accuracy for zero‐value insulators in distribution lines, this study proposes a novel method for detecting these insulators based on the electroluminescence effect. Through theoretical analysis and experimentation, it was found that the luminescence intensity of ZnS:Cu electroluminescent material varies ...
Jianghai Geng +6 more
wiley +1 more source

