Diabetes Mellitus: Evaluation of Cornea Biomechanics with Corvis-ST
Abstract Objective: We conducted the present work to evaluate cornea biomechanics, using Corvis-ST device parameters amongst patients with diabetes mellitus.Methods: In this cross-sectional study, 62 type II diabetic patients and 28 non-diabetic individuals were recruited.
Amir masood Rafie manzelat +3 more
openaire +1 more source
Relationship of Corneal Biomechanics Measured by Corvis ST and Optic Nerve Head Parameters in Healthy Saudi Females. [PDF]
Amira Elagamy,1,2 Hessa Khaled Alnasser,3 Wafa Saeed Alghamdi,3 Mohamed Berika,4,5 Dara Aldisi6 1Department of Optometry and Vision Sciences, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia; 2Mansoura Ophthalmic Center ...
Elagamy A +4 more
europepmc +2 more sources
The Effect of Upper Eyelid Blepharoplasty on Corneal Biomechanical Parameters Measured by Corvis ST. [PDF]
Abstract Purpose: To determine the effect of upper eyelid blepharoplasty (UEB) surgery on corneal biomechanical parameters 4 months after the procedure. Methods: In this prospective longitudinal study, numerous corneal biomechanical parameters were evaluated before and 4 ...
Rafizadeh SM +4 more
europepmc +4 more sources
Corneal biomechanical parameters were compared in 100 keratoconus eyes with abnormal elevation on the back corneal surface only (group 1), versus both the back and front surfaces (group 2).
Mohammad-Reza Sedaghat +5 more
doaj +1 more source
Corneal Biomechanical Properties in Varying Severities of Myopia
Purpose: To investigate corneal biomechanical response parameters in varying degrees of myopia and their correlation with corneal geometrical parameters and axial length.Methods: In this prospective cross-sectional study, 172 eyes of 172 subjects, the ...
Mohammad-Reza Sedaghat +9 more
doaj +1 more source
Purpose: To assess the changes in biomechanical properties of the cornea after treatment of keratoconus patients with UV-A/riboflavin corneal collagen cross-linking (CXL) using Corvis ST (Oculus, Wetzlar, Germany) and Ocular Response Analyzer (ORA ...
Ramin Salouti +4 more
doaj +1 more source
Purpose. To evaluate the corneal biomechanical properties using the CORVIS ST device (Oculus, Germany) in patients with myopia and myopic astigmatism with intact cornea as well as in patients with myopia and myopic astigmatism who underwent excimer laser
V. D. Antonuk, T. S. Kuznetsova
doaj +1 more source
Air puff deformation parameters from Corvis ST.
Air puff deformation parameters from Corvis ST.
Andrés de la Hoz (3280608) +3 more
core +1 more source
Evaluation of corneal elastic modulus based on Corneal Visualization Scheimpflug Technology
Background Corneal biomechanical properties are important for the diagnosis of corneal diseases, individualized design and prognosis of corneal surgery.
Xiao Qin +4 more
doaj +1 more source
Objective: to analyze the tonometric data, obtained with standard contactless tonometry and corneal-compensated tonometry, examined by the Oculus CorVis ST device in different groups of patients of the Tri-Z Krasnodar Clinic.Patients and Methods.
A. S. Apostolova +4 more
doaj +1 more source