Results 41 to 50 of about 1,134 (119)
Diffusion‐Generated Image Detection via Targeted Mask‐Based Knowledge Distillation
A detector that leverages reconstruction feature patterns shared across images generated by diverse diffusion models to distinguish diffusion‐generated images with minimized computational overhead. ABSTRACT Diffusion‐generated image detection aims to assess the authenticity of visual content.
Yuanyuan Huang +5 more
wiley +1 more source
Subject To assess the precision (repeatability and reproducibility) and agreement of central corneal thickness (CCT) measurements by a high‐resolution ultrasound (E‐pach), a standard ultrasound, and two Scheimpflug pachymeters in healthy eyes. Methods Instrument diagnostic test study. A total of 100 healthy volunteers were enrolled to measure right‐eye
Anqi Liu +9 more
wiley +1 more source
Abstract In human health risk assessment of chemicals and pharmaceuticals, identification of genotoxicity hazard usually starts with a standard battery of in vitro genotoxicity tests, which is needed to cover all genotoxicity endpoints. The individual tests included in the battery are not designed to pick up all endpoints.
Mirjam Luijten +15 more
wiley +1 more source
Regional corneal biomechanics assessment as a function of age using Strain–Stress Index maps
Abstract Purpose To gain a better understanding of corneal Stress–Strain Index (SSI) maps in healthy eyes and to determine their changes with age. Method The eyes of 72 participants (age 43.1 ± 20.9 years, 69.5% female) were included in the analysis, considering the left and right eyes separately.
Vahoura Tahsini +6 more
wiley +1 more source
ABSTRACT This study aimed to evaluate the genotoxic effects of food contaminants exposure in human neuroblastoma SH‐SY5Y cells using the micronucleus (MN) assay and Ames test. Acrylamide (AA), penitrem A (PEN A), and 3‐acetyldeoxynivalenol (3‐ADON) were tested both individually and in combination.
Luna Bridgeman +4 more
wiley +1 more source
Background The Corneal Visualization Scheimpflug Technology (Corvis ST) is a noncontact tonometer that enables quantitative assessment of dynamic corneal deformation.
Osama Z. Shousha +3 more
doaj +1 more source
INTRODUCTION: To examine the repeatability of central corneal thickness (CCT) measurements by corneal dynamic Scheimpflug analyzer Corvis ST (Corvis), RTVue anterior segment optical coherence tomography (OCT) and Sirius corneal topography (Sirius) in ...
Mustafa Kosker +5 more
doaj +1 more source
Minimally Invasive Glaucoma Surgery Procedure in the Human Eye. A Fluid Structure Interaction Study
The implantation of a microstent for glaucoma surgery has been successfully simulated for the first time. A Fluid‐Structure Interaction (FSI) simulation is introduced to model aqueous humor flow dynamics post‐surgery, enabling a detailed analysis of the microstent's interaction with ocular tissues and fluids.
Elena Redaelli +4 more
wiley +1 more source
Purpose. To assess the repeatability and reproducibility of dynamic corneal response parameters measured by the Corvis ST (Oculus, Wetzlar, Germany). Methods. One eye randomly selected from 32 healthy volunteers was examined by the Corvis ST.
Bernardo T. Lopes +8 more
doaj +1 more source
Introduction: The objective is to evaluate the concordance of intraocular pressure (IOP) values by comparing three tonometers; Corvis ST (COR), Icare Pro (ICA) and Tonopen (TOP) with the gold standard, the Goldmann applanation tonometry (GAT and the ...
Patricia Hernandez Mendieta +3 more
doaj +1 more source