Results 211 to 220 of about 150,237 (223)
Abstract Purpose The purpose of the present study was to evaluate the impact of bone relative electron density (rED) assignment on radiotherapy planning for the abdominal region. Methods Twenty patients who received abdominal radiotherapy using MR‐Linac and underwent magnetic resonance imaging (MRI) and computed tomography (CT) simulation were analyzed.
Kota Abe+4 more
wiley +1 more source
Counselee Attitudes Toward the Counseling Process in Selected Florida Junior Colleges.
Eveleen Shriner
openalex +2 more sources
Abstract Purpose This study evaluates a novel cone‐beam computed tomography (CBCT) imaging solution integrated onto a conventional C‐arm linear accelerator (linac) with increased gantry speed. The purpose is to assess the impact of improved imaging hardware and reconstruction algorithms on image quality.
Theodore Arsenault+9 more
wiley +1 more source
Abstract Current radiotherapy practices rely on manual contouring of CT scans, which is time‐consuming, prone to variability, and requires highly trained experts. There is a need for more efficient and consistent contouring methods. This study evaluated the performance of the Varian Ethos AI auto‐contouring tool to assess its potential integration into
Robert N. Finnegan+6 more
wiley +1 more source
Methods for working with problem residents in medical physics residency education
Abstract Medical physics residency training programs may occasionally encounter residents requiring additional intervention beyond normal training efforts. In the literature, these residents are referred to as “problem” residents. While the physician literature on the subject is valuable, this paper specifically focuses on dealing with a problem ...
Christopher J. Watchman, Dandan Zheng
wiley +1 more source
Abstract Introduction Many artificial intelligence (AI) solutions have been proposed to enhance the radiotherapy (RT) workflow, but limited applications have been implemented to date, suggesting an implementation gap. One contributing factor to this gap is a misalignment between AI systems and their users.
Luca M. Heising+11 more
wiley +1 more source
In vivo transit dosimetry methodology for whole breast intensity modulated radiation therapy
Abstract Background In vivo transit dosimetry using an electronic portal imaging device (EPID‐IVTD) is an important tool for verifying the accuracy of radiation therapy treatments. Despite its potential, the implementation of EPID‐IVTD in breast intensity modulated radiation therapy (IMRT) treatments has not yet been standardized, limiting its clinical
Lucia Zirone+8 more
wiley +1 more source
Facilitating 1.5T MR‐Linac adoption: Workflow strategies and practical tips
Abstract Background MR‐guided radiotherapy (MRgRT) offers new opportunities but also introduces workflow complexities requiring dedicated optimization. Implementing magnetic resonance linear accelerator (MR‐Linac) technology comes with challenges such as prolonged treatment times and workflow integration issues.
Madeline Michel+9 more
wiley +1 more source
Abstract Purpose This study quantitatively evaluates bladder changes and their dosimetric impact during the on‐couch adaptive process on a commercial CBCT‐based online adaptive radiotherapy (CT‐gART) platform. Methods Data from 183 fractions of ten patients receiving online ART for pelvic cancers were analyzed retrospectively.
Ingrid Valencia Lozano+7 more
wiley +1 more source