Results 71 to 80 of about 731,305 (291)

Direct determination of lead-210 by liquid-scintillation counting [PDF]

open access: yes, 1969
Soft betas, the internal conversion electrons, and unconverted gamma rays from lead-210 are efficiently detected in a liquid scintillation counting system with efficiency of 97 percent. The counter is interfaced with a multichannel pulse height analyzer.
Fairman, W. D., Sedlet, J.
core   +1 more source

Characterization of a commercially available large area, high detection efficiency single-photon avalanche diode

open access: yes, 2013
We characterize a new commercial, back-illuminated reach-through silicon single-photon avalanche photo diode (SPAD) SAP500 (Laser Components. Inc.), operated in Geiger-mode for purpose of photon counting.
Stipčević, Mario   +2 more
core   +1 more source

Genetic attenuation of ALDH1A1 increases metastatic potential and aggressiveness in colorectal cancer

open access: yesMolecular Oncology, EarlyView.
Aldehyde dehydrogenase 1A1 (ALDH1A1) is a cancer stem cell marker in several malignancies. We established a novel epithelial cell line from rectal adenocarcinoma with unique overexpression of this enzyme. Genetic attenuation of ALDH1A1 led to increased invasive capacity and metastatic potential, the inhibition of proliferation activity, and ultimately ...
Martina Poturnajova   +25 more
wiley   +1 more source

Surgical instrument counting: Current practice and staff perspectives on technological support

open access: yesHuman Factors in Healthcare
Background: Surgical instrument counting is a manual, attention-intensive task of the operating room (OR) nurse. Many labour-saving technologies have been proposed, but implementation remains challenging.
A.M. Kooijmans   +3 more
doaj   +1 more source

Simultaneous readout of two charge qubits

open access: yes, 2006
We consider a system of two solid state charge qubits, coupled to a single read-out device, consisting of a single-electron transistor (SET). The conductance of each tunnel junction is influenced by its neighboring qubit, and thus the current through the
A. A. Clerk   +7 more
core   +1 more source

Efficient Representation and Counting of Antipower Factors in Words [PDF]

open access: yesInformation and Computation, 2019
Full version of a paper from LATA ...
Tomasz Kociumaka   +5 more
openaire   +3 more sources

Dimethyl fumarate combined with cisplatin at subcytotoxic doses sensitizes cervical cancer toward ferroptosis and apoptosis through GSH restriction and p53 (re)activation

open access: yesMolecular Oncology, EarlyView.
Dimethyl fumarate (DMF) reduces growth of HPV‐positive cervical cancer spheroids and induces ferroptosis in cervical cancer cells via blocking SLC7A11/Glutathione (GSH) axis. Combination of subcytotoxic doses of DMF and cisplatin (CDDP) further suppresses spheroid growth and drives cell death in 2D culture models.
Carolina Punziano   +6 more
wiley   +1 more source

Targeted modulation of IGFL2‐AS1 reveals its translational potential in cervical adenocarcinoma

open access: yesMolecular Oncology, EarlyView.
Cervical adenocarcinoma patients face worse outcomes than squamous cell carcinoma counterparts despite similar treatment. The identification of IGFL2‐AS1's differential expression provides a molecular basis for distinguishing these histotypes, paving the way for personalized therapies and improved survival in vulnerable populations globally.
Ricardo Cesar Cintra   +6 more
wiley   +1 more source

Research on sit-up counting method and system based on human skeleton key point detection

open access: yesQuality in Sport
This paper proposes a sit-up counting system based on bone key point detection, aiming to solve the subjectivity and inefficiency problems of traditional manual counting.
Zhiming Shi   +3 more
doaj   +1 more source

Optimisation of the Read-out Electronics of Muon Drift-Tube Chambers for Very High Background Rates at HL-LHC and Future Colliders

open access: yes, 2016
In the ATLAS Muon Spectrometer, Monitored Drift Tube (MDT) chambers and sMDT chambers with half of the tube diameter of the MDTs are used for precision muon track reconstruction.
Abovyan, Sergey   +12 more
core   +1 more source

Home - About - Disclaimer - Privacy