Results 291 to 300 of about 11,810,041 (377)

Position‐dependent offset corrections for ring applicator reconstruction in cervical cancer brachytherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Due to the tight curvature in their design, ring applicators are usually associated with large positioning errors. The standard practice to correct for these deviations based on global offsets may not be sufficient to comply with the recommended tolerance.
Leon G. Aldrovandi   +3 more
wiley   +1 more source

A Python package for fast GPU‐based proton pencil beam dose calculation

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Open‐source GPU‐based Monte Carlo (MC) proton dose calculation algorithms provide high speed and unparalleled accuracy but can be complex to integrate with new applications and remain slower than GPU‐based pencil beam (PB) methods, which sacrifice some physical accuracy for sub‐second plan calculation.
Mahasweta Bhattacharya   +4 more
wiley   +1 more source

Using deep learning generated CBCT contours for online dose assessment of prostate SABR treatments

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Prostate Stereotactic Ablative Body Radiotherapy (SABR) is an ultra‐hypofractionated treatment where small setup errors can lead to higher doses to organs at risk (OARs). Although bowel and bladder preparation protocols reduce inter‐fraction variability, inconsistent patient adherence still results in OAR variability.
Conor Sinclair Smith   +8 more
wiley   +1 more source

An investigation into the feasibility and efficacy of stereotactic radiosurgery for 1–3 cm single brain lesions on the ring‐mounted Halcyon LINAC

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose An evaluation of the accuracy, safety, and efficiency of the Halcyon ring delivery system (RDS) for stereotactic radiosurgery (SRS) treatment to relatively small (1–3 cm) brain lesions. Methods After completing the extensive in‐house quality assurance checks including Winston–Lutz test and independent dose verification via MD Anderson ...
Kate Hazelwood   +5 more
wiley   +1 more source

Microgravity and Cellular Biology: Insights into Cellular Responses and Implications for Human Health. [PDF]

open access: yesInt J Mol Sci
López Garzón NA   +6 more
europepmc   +1 more source

JACMP 2025–2029 and beyond

open access: yes
Journal of Applied Clinical Medical Physics, EarlyView.
Michael Mills
wiley   +1 more source

Home - About - Disclaimer - Privacy