The reliable operation of high-voltage power cables largely depends on accurately predicting the internal electric field distribution under complex service conditions. In cross-linked polyethylene (XLPE) insulated cables, prolonged direct current or quasi-direct current operation can induce significant thermal gradients and moisture ingress, leading to
Ping Huang +5 more
openaire +1 more source
Partial discharge behaviour of cross-linked polyethylene - natural rubber blends nanocomposites as electrical insulating material [PDF]
Polymeric materials are widely used in power apparatus as electrical insulation, especially for high voltage cable insulation. However, partial discharge (PD) has always been a predecessor to major faults and problems in this field.
Wan Mohd. Zawawi, Wan Akmal ‘Izzati
core
The space charge accumulation in the heterogeneous insulation composed of cross‐linked polyethylene (XLPE) cable and silicone rubber (SiR) accessory poses a serious threat to the safe operation of the high voltage direct current (HVDC) cable.
Yani Wang +6 more
doaj +1 more source
This work studies the chemical composition, physical make-up, and aging mechanisms of thermally-exposed and gamma-irradiated, commercial, cross-linked, polyethylene (XLPE) cable insulation material used in Nuclear Power Plants (NPPs), using various analytical characterization techniques.
openaire +3 more sources
Condition Monitoring of Power Cables
A National Grid funded research project at Southampton has investigated possible methodologies for data acquisition, transmission and processing that will facilitate on-line continuous monitoring of partial discharges in high voltage polymeric cable ...
Hao, L +3 more
core
Association of antioxidant-added highly cross-linked polyethylene on revision risk: a registry-based study of 198,073 total hip replacements from the Australian Orthopaedic Association National Joint Replacement Registry between 2014 and 2023. [PDF]
Lewis PL +5 more
europepmc +1 more source
Comparisons of Thermo-Oxidative Ageing Performance and Lifespan Evaluation of Grafted Polypropylene and XLPE Cables: Combined Effect of Temperature and Thickness. [PDF]
Zhang W +6 more
europepmc +1 more source
Fracture of Dual-Mobility Polyethylene Liner in a Primary Total Hip Arthroplasty: A New Complication to a Modern Design: A Case Report. [PDF]
Bailey EP +5 more
europepmc +1 more source
Does the rate of revision vary in primary total stemmed anatomic shoulder arthroplasty with short or conventional humeral stems? [PDF]
Gill DRJ, Corfield S, Du P, Bokor DJ.
europepmc +1 more source
Analysis on the thermal performance and economic efficiency of XLPE submarine cable based on electric-thermal-hydraulic coupling simulation. [PDF]
Ye M, Zhang Y, Wu H, Zeng C, Chen H.
europepmc +1 more source

