Results 81 to 90 of about 107,549 (340)

Coherent Control of Nitrogen Nuclear Spins via the VB−${\rm V}_B^-$‐Center in Hexagonal Boron Nitride

open access: yesAdvanced Functional Materials, EarlyView.
This study demonstrates coherent control of 15N nuclear spins coupled to VB−${\text{V}}_{\text{B}}^{-}$ centers in isotope‐enriched hexagonal boron nitride. Selective addressing via spin‐state mixing enables Rabi driving, quantum gates, and coherence times exceeding 10 μs$\umu{\rm s}$.
Adalbert Tibiássy   +6 more
wiley   +1 more source

Prescripción de lente de contacto en niños de Las Tunas

open access: yesRevista Electrónica Dr. Zoilo E. Marinello Vidaurreta, 2016
Fundamento:el empleo de lentes de contacto se ha incrementado a nivel mundial; en la actualidad su uso no se restringe solamente a la corrección óptica, sino que se utilizan con fines terapéuticos, ya que generan comodidad y estética en múltiples ...
Yusimy Agüero Viamontes   +2 more
doaj  

Migrated subconjunctival crystalline lens: a traumatic phacocele [PDF]

open access: bronze, 2020
Swechya Neupane   +2 more
openalex   +1 more source

Digital Actuation Control of Soft Robotic Origami With Self‐Folding Liquid Crystal Elastomer Hinges

open access: yesAdvanced Functional Materials, EarlyView.
Self‐folding soft‐rigid hybrid robotic origami is enabled by liquid crystal elastomer actuators with embedded Joule heating and closed‐loop digital control. Digitally addressable hinges provide reversible and programmable transitions between distinct folded states while maintaining actuation performance at high cycle counts (over 1500).
David C. Bershadsky   +3 more
wiley   +1 more source

A new curved vitreous cutter for managing phakic retinal detachment with proliferative vitreoretinopathy

open access: yesIndian Journal of Ophthalmology, 1998
In the presence of proliferations anteriorly, adequate excision of the vitreous base is essential. To enable a good vitreous base excision, removal of lens often becomes necessary as it may be damaged while attempting to remove peripheral vitreous.
Natarajan S   +2 more
doaj  

Scalable Thermal Engineering via Femtosecond Laser‐Direct‐Written Phononic Nanostructures

open access: yesAdvanced Functional Materials, EarlyView.
This study demonstrates that femtosecond laser‐induced periodic surface structures (fs‐LIPSS) can function as phononic metasurfaces, reducing thermal conductivity below the plain thin‐film limit. Phonon Monte Carlo analysis reveals that the periodic structures restrict phonon mean free paths.
Hiroki Hamma   +4 more
wiley   +1 more source

Phakic Intraocular Lenses An Overview

open access: yesDelhi Journal of Ophthalmology, 2013
Currently, there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery, and implantation of an intraocular lens (IOL) in the anterior or posterior chamber.
Sana Ilyas Tinwala, J S Titiyal
doaj   +1 more source

Control of the Casimir Force Using Semiconductor Test Bodies

open access: yes, 2011
We describe experimental and related theoretical work on the measurement of the Casimir force using semiconductor test bodies. This field of research started in 2005 and several important and interesting results have already been obtained.
Klimchitskaya, G. L.   +2 more
core   +1 more source

Universal Electronic‐Structure Relationship Governing Intrinsic Magnetic Properties in Permanent Magnets

open access: yesAdvanced Functional Materials, EarlyView.
Permanent magnets derive their extraordinary strength from deep, universal electronic‐structure principles that control magnetization, anisotropy, and intrinsic performance. This work uncovers those governing rules, examines modern modeling and AI‐driven discovery methods, identifies critical bottlenecks, and reveals electronic fingerprints shared ...
Prashant Singh
wiley   +1 more source

Home - About - Disclaimer - Privacy