Results 11 to 20 of about 3,341 (115)
ABSTRACT Early diagnosis of liver cancer demands high sensitivity, high specificity, convenience and real‐time monitoring capabilities. However, it encounters challenges such as low concentration of markers, numerous interfering factors, and limitations of detection technologies.
Changsheng Shi +10 more
wiley +1 more source
ABSTRACT This study demonstrates a new strategy for modifying the boron content to address stress‐relief cracking (SRC) in the 7CrMoVTiB10.10 alloy. First, coarse‐grained heat‐affected zone (CGHAZ) specimens with different boron contents were prepared via simulated welding thermal cycles.
Dongdong Zhang +3 more
wiley +1 more source
ABSTRACT Porous NiTi alloys are widely used in biomedical and engineering fields. Using the PBF‐LB technique, the TPMS and Voronoi porous parts with a porosity of ∼67% and a minimum feature size of 0.15 ± 0.02 mm were fabricated. Although the bulk sample fabricated with the same parameters is defect‐free, μ‐CT reconstruction on the porous sample ...
Wen‐Hao Zeng +7 more
wiley +1 more source
目的通过对低剂量CT窦道造影扫描与常规CT扫描的辐射剂量、图像质量及病灶的显示情况的对比研究,探讨低剂量CT窦道造影扫描在臀部窦道中的应用价值。方法搜集2012年3月至2017年10月在本院诊断为臀部窦道的患者78例,随机分为A、B两组,窦道造影前后均行CT扫描,造影前均采用常规剂量(120kV,200mA)扫描,造影后两组分别采用100mA和50mA的低剂量扫描,其他参数保持一致。通过统计学方法比较低剂量造影扫描和常规扫描的辐射剂量、图像质量及病灶的显示情况等。结果 ...
方进智 +4 more
doaj
ABSTRACT Objective To test the non‐inferiority of extended abdominopelvic ultrasound examination compared with contrast‐enhanced computed tomography (CT) and whole‐body diffusion‐weighted magnetic resonance imaging (WB‐DWI/MRI) in discriminating preoperatively between resectable and non‐resectable disease based on the European Society for Medical ...
D. Fischerova +26 more
wiley +1 more source
CT扫描联合酶联免疫吸附法检测血清AFP-L3含量在PHC诊断中的价值
目的通过CT扫描联合酶联免疫吸附法(ELISA)检测血清甲胎蛋白异质体(AFP-L3)含量,探讨其在原发性肝癌(PHC)诊断中的价值。方法137例(其中106例具CT增强扫描的资料)血清标本来自唐山市人民医院2011年3月至11月间的住院患者,运用ELISA法检测血清中AFP-L3的含量,以AFP-L3>37.89ng/ml为临界值。137例病例均具有CT或CT增强扫描资料,回顾分析137例患者总共164个PHC病灶的增强扫描经后处理技术得到二维及三维重建图像而诊断,探讨采用血清AFP ...
李玉柱 +7 more
doaj
Yttrium Addition Co‐Enhances the Plasticity and Corrosion Resistance of TiB2‐Refined Al‐Mg‐Zn Alloys
ABSTRACT To address the degradation of corrosion resistance induced by Al‐5Ti‐B grain refiner during the strengthening of Al‐Mg‐Zn alloys, this study innovatively employed a rare earth element yttrium (Y) alloying strategy to achieve synergistic enhancement of mechanical strength and corrosion resistance.
Wen‐Tao Qin +9 more
wiley +1 more source
目的探讨肋骨骨折低剂量多层螺旋CT扫描的最佳参数。方法将30名志愿者随机分为3组,分别行低剂量螺旋CT扫描,管电流分别设置为100 mA、50 mA及25 mA,扫描后行薄层及VR、MPR重建,由三位不同年资医师分别进行影像分析,并进行不同管电流组间统计学秩和检验(Kruskal Wallis检验),选取最佳低剂量扫描参数。再选择10例肋骨骨折患者利用最佳扫描参数进行检查以判断其对于诊断肋骨骨折的可靠性。结果统计学表明,χ2=18.921,P=0.000,三组间差异均有统计学意义。100 mA、50 ...
刘岳峰 +4 more
doaj
双能量CT结合能谱纯化SPS Ⅱ及ADMIRE迭代技术在痛风结晶诊断上的应用价值
2015年美国风湿病学会联合欧洲抗风湿病联盟(ACR/EULAR)确定的痛风分级标准中,超声和双能CT尿酸盐沉积成像被纳入重要诊断依据[1]。在许多研究中,双能量CT(DECT)已经被证明能够高精度检测单钠尿酸(MSU)晶体[2]。目前已有5种不同类型的DECT扫描仪可供选择:双源DECT、带金滤波器的双束单源CT、带宝石闪烁探测器的快速千伏开关源CT、双层多检测器DECT和双扫描单源CT[3]。
胡真真 +4 more
doaj
ABSTRACT Objective To determine the diagnostic accuracy of virtual autopsy using whole‐body postmortem ultra‐high field magnetic resonance imaging (MRI) at 7 Tesla (T), using a short T2‐weighted imaging (T2‐WI) protocol, compared with classical autopsy, for detecting structural abnormalities in small second‐trimester fetuses. Methods Thirty consecutive
A. Staicu +11 more
wiley +1 more source

