Results 11 to 20 of about 1,138,456 (310)

Extra‐sensitive impedance differential protection immune to CT saturation

open access: yesIET Generation, Transmission & Distribution, 2020
For extra‐high voltage transmission lines configured with a communication channel, the current differential protection is facing a dilemma between sensitivity and security. On the one hand, the resistive coverage will not be sufficiently high if security
Ning Tong   +6 more
doaj   +2 more sources

Impact of CT saturation on overcurrent relays

open access: yesThe Journal of Engineering, 2018
An overcurrent relay analyses and processes the secondary currents from a set of current transformers (CTs) and if the currents exceed the operating threshold initiates the tripping of a circuit breaker after an appropriate time. An important issue for a protection relay is how it responds when the steel core of the CT is saturated. The exact behaviour
Yanjun Ma, Peter Crossley
openaire   +1 more source

An Accurate CT Saturation Classification Using a Deep Learning Approach Based on Unsupervised Feature Extraction and Supervised Fine-Tuning Strategy

open access: yesEnergies, 2017
Current transformer (CT) saturation is one of the significant problems for protection engineers. If CT saturation is not tackled properly, it can cause a disastrous effect on the stability of the power system, and may even create a complete blackout.
Muhammad Ali   +3 more
doaj   +1 more source

EVALUATION OF CURRENT SIGNALS AT OBSERVED POINTS OF THE ELECTRICAL NETWORK IN PROBLEMS OF IDENTIFICATION OF CURRENT TRANSFORMER SATURATION

open access: yesВестник Северо-Кавказского федерального университета, 2022
Despite the fact that the problem of saturation of current transformers (CT) has been known for a long time, it has not lost its relevance now. Cases of malfunctioning as a result of oversaturation of CT are still recorded today.
P. Shagimardanov
doaj   +1 more source

Experimental Study on the Shear Band of Methane Hydrate-Bearing Sediment

open access: yesJournal of Marine Science and Engineering, 2021
The occurrence of a shear band is often thought as the precursor of failure. To study the initiation of shear banding in gas hydrate-bearing sediments, two groups of triaxial compression tests combined with a CT (computer tomography) scan were conducted ...
Xiaobing Lu   +5 more
doaj   +1 more source

Integrated busbar protection scheme utilizing a numerical technique based on coherence method

open access: yesThe Journal of Engineering, 2022
A Busbar (BB) is one of the most important elements of a power system, which links a variety of elements such as generators, power transformers, transmission lines and loads.
R. A. Mahmoud
doaj   +1 more source

Research on oil displacement mechanism in conglomerate using CT scanning method

open access: yesPetroleum Exploration and Development, 2014
Taking the conglomerate from Xinjiang Oilfield as study object, the porosity distribution characteristics of the conglomerate were analyzed with CT scanning; through the online monitoring of the water and polymer flooding process in a conglomerate core ...
Shiguan DENG   +9 more
doaj   +1 more source

Saturation Detection-Based Blocking Scheme for Transformer Differential Protection

open access: yesEnergies, 2014
This paper describes a current differential relay for transformer protection that operates in conjunction with a core saturation detection-based blocking algorithm.
Byung Eun Lee   +5 more
doaj   +1 more source

PLA Films Containing Montmorillonite Nanoclay–Citronella Essential Oil Hybrids for Potential Active Film Formulation

open access: yesMacromol, 2023
This work evaluated the synergistic effect of citronella essential oil (Ct) and montmorillonite (MMT) (called hybrid compound) incorporated in Poly(lactic acid) (PLA) films at different concentrations (3, 10, 15, and 20 wt%). PLA films were characterized
Rafaela R. Ferreira   +3 more
doaj   +1 more source

The test bench for simulation impact of core saturation on the current transformer on coordination of inverse relay protection [PDF]

open access: yesE3S Web of Conferences
When the measurement-type Current Transformer (CT) is used for protection schemes, this condition causes problems related to the operation of the protection relay.
Supriyanto, Utomo Heri Budi, Sunarto
doaj   +1 more source