FPGA-Based Smart Sensor to Detect Current Transformer Saturation during Inrush Current Measurement [PDF]
Current transformer saturation affects measurement accuracy and, consequently, protection reliability. One important concern in the case of overcurrent protections is the discrimination between faults and inrush current in power transformers.
G. de J. Martínez-Figueroa +2 more
doaj +4 more sources
Current Transformer Saturation Detection Method Based on Artificial Neural Network [PDF]
When current transformer is saturated, mainly due to the presence of an exponentially decaying DC component in the fault current, its secondary current has a distinctive distorted waveform which significantly differs from its primary (true) waveform.
Yu. V. Rumiantsev
doaj +2 more sources
Current transformer (CT) saturation classification using empirical mode decomposition (EMD) and relevance vector machine (RVM) [PDF]
The fault is taking place in the power system where the saturation of the Current Transformer (CT) is occurring, among other variations of system parameters.
Nilesh Chothani +3 more
doaj +2 more sources
Substation protection method for missing measurement information of transformer and bus connecting line [PDF]
In order to solve the problems of protection misoperation and refusing to operate caused by the lack of measurement information in smart substation, a substation protection method which can effectively eliminate the influence of transformer inrush ...
Liu Wei +8 more
doaj +1 more source
The study on the Mal-operation of the transformer current differential protection during external faults cause by CT saturation [PDF]
This paper analyses the unusual mal-operation of the differential protection for transformer current differential protection during the external fault. The mal-operation reason is researched in detail, based on the mathematical analysis, the simulation ...
Wu Jianhong +5 more
doaj +1 more source
Analysis of operation of transformer differential protection under current transformer saturation: Software simulations and relay testing [PDF]
In the paper the analyses of the current transformer saturation influence to operation of differential protection are presented. Analyses are performed using a simulation tool and a relay model, as well as using the physical relay by injecting test ...
Sučević Nikola +2 more
doaj +1 more source
Prevention of the current transformer saturation by using negative resistance
In the power grid, various conditions may occur that saturate the core of a current transformer. Saturation of the protection core of the current transformers can cause a malfunction in the protection relays.
Saeed Sanati, Yousef Alinejad‐Beromi
doaj +1 more source
Transmission Line Distance Protection Under Current Transformer Saturation
Conventional transmission line distance protection approaches are subject to malfunction under reverse fault-induced current transformer (CT) saturation for the typically employed breaker-and-a-half configuration.
Yuping Zheng +5 more
doaj +1 more source
Since the fault current output from the doubly-fed wind farm has frequency deviation characteristics and contains large harmonic components, when an internal fault occurs in the transmission transformer for the doubly-fed wind farm, the ratio of the ...
Yanchun XU +3 more
doaj +1 more source
Despite the fact that the problem of saturation of current transformers (CT) has been known for a long time, it has not lost its relevance now. Cases of malfunctioning as a result of oversaturation of CT are still recorded today.
P. Shagimardanov
doaj +1 more source