CURRENT TRANSFORMER ERROR COMPENSATION UNDER SATURATION CONDITION [PDF]
The paper presents a method to compensate the error of current transformer under saturation condition. Based on least square method the factor decision process is shown.
Morozenko, N. A. +7 more
core
Bayesian Deep Neural Network to Compensate for Current Transformer Saturation
Current transformer saturation has a negative effect on the operation of IEDs, resulting in their malfunction. Here, we present a technique to compensate for saturated waveforms using Bayesian Deep Neural Network (BDNN) comprising Deep Neural Network ...
Sopheap Key +3 more
doaj +1 more source
Digital Current Measurement Element for Operation During Current Transformer Severe Saturation
The development and implementation of a digital current measurement element for proper operation during current transformer (CT) magnetic core severe saturation are considered.
Yu. V. Rumiantsev +3 more
doaj +1 more source
Current transformer saturation [PDF]
V okviru magistrske naloge smo opisali različne vrste nasičenj tokovnih transformatorjev (TT) in razloge za njihov nastanek. Merjenje tokov je z vidika vodenja in zaščite naprav in omrežja nujen proces. Ker pri prenosu in distribuciji električne energije
Bevc, Jure
core
Recently, there has been an increased interest in the use of artificial neural networks in various branches of the electric power industry including relay protection.
Yu. V. Rumiantsev, F. A. Romaniuk
doaj +1 more source
Through the analysis of the recovery inrush current generated by the external fault removal of the converter transformer, it is pointed out that the zero-sequence current caused by the recovery inrush may result in the saturation of the neutral current ...
Tao Zheng +4 more
doaj +1 more source
The protection relay performs a significant role in maintaining the power system’s reliability and stability. However, Current Transformer (CT) saturation affects the overcurrent, differential and distance protection under various conditions ...
Nilesh Chothani, Swapnil Kumar
doaj +1 more source
A High-Precision Error Calibration Technique for Current Transformers under the Influence of DC Bias
A bias current in the power system will cause saturation of the measuring current transformer (CT), leading to an increase in measurement error. Therefore, in this paper, we first conducted measurements of the direct current component in a 10 kV ...
Sanlei Dang +8 more
doaj +1 more source
The.main types of wind turbines-generators in the power supply system
THE PURPOSE. This paper considers the problem of relay protection functioning when the current transformer reaches the saturation mode which is provided by transient processes.METHODS. MATLAB Simulink software environment allows reproducing the method of
V. A. Novobritsky, D. S. Fedosov
doaj +1 more source
Investigations into the transformer inrush current problem [PDF]
A transformer being energised may draw a large transient current from the grid supply, resulting in a temporary voltage dip at the point of connection (POC) where customers are connected. The voltage dip is dependent upon the magnitude of the transformer
Ekwue, A.O., Rawn, B, A.O. Ekwue, B Rawn
core +1 more source