Results 21 to 30 of about 4,985 (290)
Despite the fact that the problem of saturation of current transformers (CT) has been known for a long time, it has not lost its relevance now. Cases of malfunctioning as a result of oversaturation of CT are still recorded today.
P. Shagimardanov
doaj +1 more source
Recently, there has been an increased interest in the use of artificial neural networks in various branches of the electric power industry including relay protection.
Yu. V. Rumiantsev, F. A. Romaniuk
doaj +1 more source
Simulation of the saturation process of a current transformer with a load [PDF]
The article deals with the mathematical basis and simulation of the saturation processes of current transformers with aperiodic components of short-circuit currents. Saturation processes of current transformers can affect the correct operation of the protections.
Kirill K. Krutikov +2 more
openaire +1 more source
This article describes the parameters calculation for the three-phase two-winding power transformer model taken from the SimPowerSystems library, which is the part of the MatLab- Simulink environment.
I. V. Novash, Yu. V. Rumiantsev
doaj +2 more sources
Comparison of Mathematical Methods for Compensating a Current Signal under Current Transformers Saturation Conditions [PDF]
Current measurements from electromagnetic current transformers are essential for the construction of secondary circuit systems, including for protection systems. Magnetic core of these transformers are at risk of saturation, as a result of which maloperation of protection algorithms can possibly occur.
Ismoil Odinaev +7 more
openaire +4 more sources
Recently, there has been an increased interest in the use of artificial neural networks in various branches of the electric power industry including relay protection.
Yu. V. Rumiantsev, F. A. Romaniuk
doaj +1 more source
This paper proposes a flexible digital control scheme for isolated phase-shift full-bridge (PSFB) converters. The required transformer suffers from inevitable imbalance of magnetic flux resulting in an increased magnetizing DC-offset current that ...
Angelika Neumann +4 more
doaj +1 more source
The.main types of wind turbines-generators in the power supply system
THE PURPOSE. This paper considers the problem of relay protection functioning when the current transformer reaches the saturation mode which is provided by transient processes.METHODS. MATLAB Simulink software environment allows reproducing the method of
V. A. Novobritsky, D. S. Fedosov
doaj +1 more source
CURRENT TRANSFORMER ERROR COMPENSATION UNDER SATURATION CONDITION [PDF]
The paper presents a method to compensate the error of current transformer under saturation condition. Based on least square method the factor decision process is shown.
Morozenko, N. A. +7 more
core
Research on Transient Low-Frequency Oscillation of Electrified Railway Vehicle-Grid Coupling System
At the moment of electric locomotive passing the neutral-section, the voltage and current of traction network may have low-frequency oscillation (LFO), which will seriously affect the safe operation of the railway. Aiming at eliminating the transient LFO,
Zhiyong Li +4 more
doaj +1 more source