Results 61 to 70 of about 5,341 (200)
ABSTRACT Pediatric radiation therapy presents unique challenges compared to adult treatments, including those of immobilization, potential need for sedation, and the critical importance of accurate, reproducible positioning. Additionally, heightened attention to imaging doses is necessary to minimize long‐term toxicity in survivors.
Parham Alaei +17 more
wiley +1 more source
Development Of An Automatic Calculation Method For Ct Dose Estimation Based On Individual Specific Size In Paediatric Population [PDF]
The current dose estimation based on CTDIvol in paediatric CT leads to significant inaccuracies in dose estimation due to inadequate size consideration.
Abdulkadir, Muhammad Kabir
core +1 more source
Abstract Background A common method to estimate the effective dose in CT is to multiply the dose length product in a CT scan by a conversion factor (k). The k‐factors are determined by dividing the effective dose (calculated using a weighted summation of organ doses) by the dose length product (DLP) for specific digital phantoms.
Jelena M. Mihailovic +5 more
wiley +1 more source
Introduzione e scopo La tomografia computerizzata (CT) della SPECT/CT è una componente necessaria per la correzione dell'attenuazione (AC) e la localizzazione anatomica (AL) nell'imaging ibrido.
Roberto Rinaldi, Luca Camoni
doaj +1 more source
Prospective estimation of water equivalent diameter and SSDE using 3D landmark CT scans
Abstract Background 3D Landmark (3DLM) scans have recently been introduced in some new CT scanners for automatic scan planning instead of paired 2D localizers, with potential additional utility. Purpose The purpose of this work was to measure the accuracy and precision of 3DLM scans for determining water equivalent diameter (Dw${{D}_w}$) and size ...
Andrew M. Hernandez +6 more
wiley +1 more source
To compare hepatic parenchymal contrast media (CM) enhancement during multi-detector row computed tomography (MDCT) and its correlation with volume pitch-corrected computed tomography dose index CTDIvol) and body weight (BW).
Björk, Jonas, +6 more
core +1 more source
Computed Tomography (CT) is an indispensable diagnostic imaging system, but it contributes significantly to patient radiation exposure. To safeguard patients and ensure best practice, the International Commission on Radiological Protection recommends compliance with Diagnostic Reference Levels (DRLs). The Federal Teaching Hospital Birnin Kebbi (FTHBK),
Garba I. I. +3 more
openaire +2 more sources
Radiation intensity () and visibility of anatomical structures in head CT examinations [PDF]
The purpose of this study was to quantify how changing the amount of radiation used to perform routine head CT examinations () affects visibility of key anatomical structures. Eight routine noncontrast head CT exams were selected from six CT scanners, each of which had a different setting (60 to 75 mGy).
Sameer, Tipnis +5 more
openaire +2 more sources
Abstract Background Ultra‐high‐resolution (UHR) photon‐counting CT (PCCT) with small‐pixel detectors improves resolution and noise, but its dependence on diverse imaging conditions remains insufficiently characterized. Purpose To systematically evaluate the small‐pixel effect in UHR PCCT by assessing noise properties and high‐contrast spatial ...
Kyu‐Ho Song +6 more
wiley +1 more source
Purpose: The radiation dose to the patient in C-arm cone beam CT (C-arm CBCT) is delivered in a similar fashion to that by standard diagnostic CT.
Vanderhoek, Matthew, Bakalyar, Donovan
core +1 more source

