Results 81 to 90 of about 5,341 (200)
Context: Computed tomography perfusion (CTP) is an important functional tool for lung cancer. It is expected to deliver high radiation dose, making its accurate estimation important. Size-specific dose estimate (SSDE) is a new dose metric, which includes
Shuchi Bhatt +3 more
doaj +1 more source
Background In recent times, size-specific dose estimate (SSDE) has been the ideal metric for accurate estimation of individual patient doses in computed tomography (CT) examinations.
Hamza Sulemana +2 more
doaj +1 more source
Patient Dose Estimation Using CT-Expo Software at Two Hospitals in North-Central Nigeria
INTRODUCTION[|]Simulation software has aided the estimation of organ dose from computed tomography (CT) examinations. The aim of this study was to use the CT-Expo (SASCRAD, Fritz-Reuter-Weg, Buchholz, Germany) software to determine volume CT dose index ...
Mary-ann Etim Ekpo +2 more
doaj +1 more source
Dosis radiasi CT Scan menyumbang 70% Total dosis yang diterima dari pencitraan medis, tinggi atau rendahnya dosis radiasi yang diterima dapat meningkatkan risiko kanker. Untuk memastikan dosis yang diterima sebanding dengan tujuan medisnya, dosis radiasi
Lobang, Valey Jeanet +7 more
core +2 more sources
Background: Computed tomography (CT) is one of the most used imaging modalities and is one of the main sources of population exposure. Recently, patient doses are estimated through CT dose index (CTDI) phantoms as a reference to calculate CTDI volume ...
Soheila Sharifian +1 more
doaj
Analisa Perubahan kV terhadap CTDIvol Dan DLP Pada CT-Scan Kepala dengan Water Phantom
Latar belakang : Sumber radiasi pada CT scan adalah sinar-X. Kilovoltage (kV) berperan dalam menentukan tegangan tabung antara katoda dan anoda yang menentukan daya tembus sinar-X yang dihasilkan. Semakin besar kV, semakin besar nilai CTDIVol, DLP dan dosis efektif.
Anak Agung Aris Diartama +3 more
openaire +1 more source
The Effect of X-ray Energy on Dosimeter Measurements of CT Radiation Dose
Objective: The point dose and volume CT dosimetry index (CTDIvol) at different X-ray energies were measured using the Raysafe-X2 air ionization chamber (referred to as “RX2”), the Piranha CT dose profiler semiconductor ionization chamber (referred to as “
Lexin PENG +7 more
doaj +1 more source
Purpose: In brain perfusion studies, the patient's head is scanned repeatedly at one location over a short period of time to monitor contrast wash in and wash out.
Zhang, D. +6 more
core +1 more source
Radiation exposure of ovarian cancer patients : contribution of CT examinations performed on different MDCT (16 and 64 slices) scanners and image quality evaluation an observational study [PDF]
The objective of this study is to compare radiation doses given to ovarian cancer patients by different computed tomographies (CTs) and to evaluate association between doses and subjective and objective image quality.CT examinations included were ...
BRAMBILLA, SARAH +7 more
core +1 more source
Scatterplot of objective image evaluation.
Shown are mean cortical values (A), CNR (B), standard deviation of background noise (C) and CNRD (D). Symbols represent the mean and error bars the standard deviation of triplicate ROI measurements. The symbol of each protocol is color coded according to
Carsten Hackenbroch (9452471) +4 more
core +1 more source