Results 21 to 30 of about 7,754,773 (292)
Suppression strategy for rail transit ground current in transformer neutral points
The ground current of rail transit contains direct and harmonic components, which will lead to many undesirable effects on substation transformer neutral points.
Zhaoyuan Wang +5 more
doaj +1 more source
Dual three–phase synchronous reluctance motors (DTP–SynRM) have the advantages of simple structure, high power density, fast dynamic response, and small torque ripple, and have broad application prospects in flywheel batteries.
Yonghong Huang +3 more
doaj +1 more source
Dual-band WLAN Antenna Array with Integrated Bandpass Filters for Harmonic Suppression [PDF]
This paper presents the design and results of a dual-band antenna array integrated with bandpass filters. The array has a 1×2 configuration. The two bands of the array correspond to the two WLAN bands of 2.4 GHz and 5.8 GHz. Other than the two main bands,
Budimir, D. +3 more
core +1 more source
The simulation of a twelve pulse diode rectifier with saturable reactors [PDF]
A twelve pulse diode rectifier with saturable reactors to allow a degree of phase control is simulated using mathematical software. First order differential equations are solved numerically to allow calculation of line current.
Moore, P.J., King, I.G
core +3 more sources
In high performance applications, LC filter usually is added to power converter for optimizing the output current ripple characteristics of the system. However, the LCL link composed of LC filter and resistor-inductance load causes the resonance, which ...
Jian Wei +4 more
doaj +1 more source
Current Harmonic Suppression Algorithm for Asymmetric Dual Three-Phase PMSM
Based on the vector space decomposition (VSD) transformation, the currents of an asymmetric dual three-phase permanent magnet synchronous motor (ADT-PMSM) with isolated neutral points are decoupled into the torque, producing α-ß components in ...
Zhihong Wu +4 more
doaj +1 more source
In the contemporary distribution network, unbalanced and harmonic distortions have been considered some major power quality problems, which have escalated especially due to the high penetration of unbalanced and nonlinear loads. This study first analyzes
Wenli Wei +4 more
doaj +1 more source
Suppression of Harmonic Current in Magnetic Bearing–Rotor System with Redundant Structure
The magnetic bearing–rotor system has the advantages of no mechanical friction and active vibration control. A magnetic bearing with redundant structures provides an effective method to apply fault-tolerant control to the magnetic bearing–rotor system.
Baixin Cheng +4 more
openaire +2 more sources
Active Power Filter With Automatic Control Circuit For Neutral Current Harmonic Minimization Technique [QC446.3.H37 I98 2007 f rb]. [PDF]
Disertasi ini bertujuan untuk membangun penuras kuasa aktif yang cekap dan boleh dipercayai bagi meminimumkan lebihan harmonik arus neutral dan juga masalah harmonik di dalam talian neutral untuk sistem tiga fasa empat dawai. The aim of this thesis
A Bakar, Mohd Izhar
core +1 more source
Harmonic Current Suppression for PMSM by Repetitive Perfect Tracking Control
AbstractPM motor drives are widely used for high‐performance servo applications. However, the PM motor has an imperfect sinusoidal flux distribution which causes harmonic currents. Inverter dead time and current measurement error also lead to harmonic currents. The repetitive control method has been applied to current suppression.
Takahiro Nakai, Hiroshi Fujimoto
openaire +2 more sources

