Results 311 to 320 of about 10,262,280 (355)
Some of the next articles are maybe not open access.

Analyzing and Reducing Current Harmonics of AC and DC sides of Cascaded H-Bridge Converters for Electric Vehicle Charging Stations

European Conference on Cognitive Ergonomics, 2019
In this paper, average modeling is derived for both AC and DC sides of grid-tied cascaded H-bridge converter (CHB). The proposed technique uses the AC current harmonics to control and reduce the current harmonic ripples on the DC sides of the CHB ...
A. Moeini, Shuo Wang
semanticscholar   +1 more source

Input Current Ripple and Grid Current Harmonics Restraint Approach for Single-Phase Inverter Under Battery Input Condition in Residential Photovoltaic/Battery Systems

IEEE Transactions on Sustainable Energy, 2018
When an existing photovoltaic (PV) system is upgraded to a residential PV/battery system, the single-phase PV inverter under both input conditions of battery and PV should be properly controlled to restrain the input current ripple and grid-current ...
B. Liu   +7 more
semanticscholar   +1 more source

Time harmonic eddy currents in non‐linear media

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering, 1998
One way to deal with non‐linearity in the case of time harmonic excitation of the electric and magnetic fields in ferromagnetic media is to introduce an effective material to model the ferromagnetic region. This fictitious material is constant throughout a period but inhomogeneous and it takes into account the non‐linear relationship between the field ...
Paoli, Gerhard, Bíró, Oszkár
openaire   +2 more sources

A modified harmonic current vector method for harmonic contribution determination

IEEE PES Power Systems Conference and Exposition, 2004., 2005
This paper deals with the determination of customer contributions to harmonic distortion at the point of connection to the utility network. The approach proposed in this paper is derived from the common power factor practice where a load should be fully compensated at the fundamental frequency and therefore seen as resistive from the network.
B. Blazic, T. Pfajfar, I. Papic
openaire   +1 more source

Line current harmonic reduction in adjustable-speed induction motor drives by harmonic current injection

ISIE '97 Proceeding of the IEEE International Symposium on Industrial Electronics, 2002
Modern adjustable-speed, induction motor drives are responsible for contaminating electric networks with undesirable harmonics. Most of the speed controllers developed for induction motors employ a rectifier-inverter arrangement. In this arrangement, the alternating current drawn by the rectifier contains many undesirable harmonics. These harmonics may
openaire   +1 more source

Modelling, Calculation and Analysis of Electromagnetic Force and Vibroacoustic Behavior of Integer-Slot Permanent Magnet Synchronous Motor Considering Current Harmonics

Journal of Vibration Engineering & Technologies, 2022
Zhipeng Wu   +5 more
semanticscholar   +1 more source

Current induced second harmonic generation in semiconductors

Applied Physics Letters, 1995
Direct current in semiconductor is theoretically shown to be capable of doubling the frequency of the incoming optical radiation. The second order susceptibility, proportional to the current is calculated to be in the 10−14−10−13 m/V range. Applications of the novel phenomenon in probing and mapping of the current in semiconductor devices are ...
openaire   +1 more source

Valuation of harmonic current injections

2002
The number of power electronic and distorting loads, continue to grow at a rapid pace. Accompanying this growth in distortion sources is an increased sensitivity of certain types of loads to harmonic distortion, and poor power quality in general. The result is greater variance in the value loads place on a harmonic free supply, and therefore what they ...
openaire   +2 more sources

Voltage and current harmonics caused by corona

Journal of the American Institute of Electrical Engineers, 1921
THE FOLLOWING investigation was made to study the effects of corona in producing voltage and current harmonics in transmission systems. In the early work on corona in 1910 a very complete oscillographic study was made of voltage and current. It was found that the current wave of corona loss very much resembled the excitation current wave of a ...
openaire   +1 more source

Home - About - Disclaimer - Privacy