Results 21 to 30 of about 19,714,201 (367)
A Detailed Testing Procedure of Numerical Differential Protection Relay for EHV Auto Transformer
In power systems, the programmable numerical differential relays are widely used for the protection of generators, bus bars, transformers, shunt reactors, and transmission lines.
Umer Ehsan +8 more
doaj +1 more source
Modeling and Analyzing the Mutual Inductance of Rogowski Coils of Arbitrary Skeleton
There are Rogowski coils of various shapes in the on-site measurement, and it is difficult to calculate the electrical quantities of Rogowski coils of curved skeleton and circular cross-section by simulation software.
Xiaoyu Liu, Hui Huang, Chaoqun Jiao
doaj +1 more source
In a polymer electrolyte fuel cell (PEFC), the current density through the polymer electrolyte membrane (PEM) is distributed along the electrode on the membrane electrode assembly (MEA).
Yasuo YOKOUCHI +3 more
doaj +1 more source
Magnetically-coupled Current Sensor Using An Integrated Coil And A Cmos Split-drain Transistor
An integrated current sensing circuit intended for Smart-Power and embedded applications featuring galvanic isolation is implemented. It is based on magnetic detection using the CMOS compatible Split- Drain transistor (MAGFET) that provides a very ...
Fernando C. Castaldo +1 more
doaj +1 more source
FEM Analysis and Sensor-Based Measurement Scheme of Current Distribution for Grounding Electrode
The current distribution of the grounding electrode in a high-voltage direct current (HVDC) transmission system affects the state of power equipment in its vicinity, which depends on the soil resistivity and shape of the grounding electrode.
Li Zhu +5 more
doaj +1 more source
Low-Impact Current-Based Distributed Monitoring System for Medium Voltage Networks
Distribution networks are currently subject to a huge revolution in terms of assets being installed. In particular, the massive spread of renewable energy sources has drastically changed the way of approaching the grid.
Alessandro Mingotti +2 more
doaj +1 more source
Broken Bar Fault Detection in IM Operating Under No-Load Condition
This paper presents a novel method for broken rotor bar detection in a squirrel-cage induction motor (IM). The proposed method applies a single-phase AC voltage as a test signal on motor terminals, resulting in a stator backward-rotating magnetic field.
RELJIC, D. +3 more
doaj +1 more source
Bimetallic ammeter: a novel method of current measurement
An electric current flowing through a bimetallic coil heats it up, and due to thermal expansion, the coil either unwinds or winds depending on the direction of net heat transfer and the specific heat capacities of the metals used.
Uy Robert Frederik +2 more
doaj +1 more source
Conventional current transformers (CTs) suffer from nonlinearities due to their ferromagnetic cores. On one hand, it is well-known that severe core saturation may occur because of large overcurrents or unidirectional transient components: this may ...
Christian Laurano +2 more
doaj +1 more source
Measurement of the antineutrino neutral-current elastic differential cross section [PDF]
arXiv:1309.7257v1 [hep ...
Aguilar-Arevalo, AA +45 more
core +2 more sources