Results 11 to 20 of about 46,417 (263)

On the Calibration of Direct-Current Current Transformers (DCCT) [PDF]

open access: yesIEEE Transactions on Instrumentation and Measurement, 2015
Modern commercial direct-current current transformers (DCCT) can measure currents up to the kA range with accuracies better than 1E-5. We discuss here a DCCT calibration method and its implementation with commercial instruments typically employed in low resistance calibration laboratories.
CALLEGARO, LUCA   +2 more
openaire   +3 more sources

Shielded Electronic Current Transformer [PDF]

open access: yesIEEE Transactions on Instrumentation and Measurement, 2004
A current transformer with nominal ratio 10 A to 10 mA, intended for low-frequency applications, was developed. It includes an electronic device to reduce the magnetizing current, and a continuous shield in the secondary winding (coaxial cable) in order to eliminate the effect of stray capacitances. No guard-source is connected to the shield.
Slomovitz, Daniel, de Souza, Heriguatí
openaire   +2 more sources

Hysteresis Parameter Identification of J-A Model Current Transformer Based on Improved Whale Algorithm

open access: yesZhongguo dianli, 2022
The accurate and rapid identification of model parameters is crucial to the simulation of the hysteresis characteristics of current transformer cores based on the J-A hysteresis model.
Yilun LI, Yishu ZHANG, Guang SONG
doaj   +1 more source

The.main types of wind turbines-generators in the power supply system

open access: yesИзвестия высших учебных заведений: Проблемы энергетики, 2022
THE PURPOSE. This paper considers the problem of relay protection functioning when the current transformer reaches the saturation mode which is provided by transient processes.METHODS. MATLAB Simulink software environment allows reproducing the method of
V. A. Novobritsky, D. S. Fedosov
doaj   +1 more source

Parameter Optimization Design of Light induction Power-taking Device for Transmission Cable

open access: yesJournal of Harbin University of Science and Technology, 2021
Current transformer induction power generation has the advantages of strong practicability, wide range of use and high safety, and it is expected to become the most effective energy supply method for online monitoring equipment of power system ...
LIN Jin-shu   +4 more
doaj   +1 more source

Wide Bandwidth and Inexpensive Current Sensor for Power Electronics—An Augmented LEM Current Sensor

open access: yesEnergies, 2021
This paper presents the overall concept of a wideband and cost-effective current sensor. The sensor consists of a paralleled Hall-based current sensor (LEM) and a wideband current transformer (CT).
Maciej Chojowski   +5 more
doaj   +1 more source

Technique of Performance Improvement of the Microprocessor-Based Protection Measuring Element

open access: yesИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика, 2019
The technique is proposed to improve the performance of the measuring element of microprocessor-based protection and its implementation is considered at the software level.
F. A. Romaniuk   +3 more
doaj   +1 more source

High-Frequency Current Transformers Cascade for Power Electronics Measurements

open access: yesSensors, 2022
High-frequency current transformers (HFCT) are widely used to measure fast transient current. Their advantages are simple structure and relatively moderate price.
Maciej Chojowski   +3 more
doaj   +1 more source

A COMPREHENSIVE MODEL FOR THE POWER TRANSFORMER DIGITAL DIFFERENTIAL PROTECTION FUNCTIONING RESEARCH

open access: yesИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика, 2016
This article presents a comprehensive model for the two-winding power transformer digital differential protection functioning research. Considered comprehensive model is developed in MatLab-Simulink dynamic simulation environment with the help of ...
Yu. V. Rumiantsev
doaj   +1 more source

Insulation Fault Caused by Current Transformer Seal Failure

open access: yesZhongguo dianli, 2020
Firstly, the insulation structures of oil-immersed current transformer (TA) and SF6 TA are introduced. And then, the causes of TA insulation breakdowns are analyzed based on an investigation of the insulation faults of TAs occurring in several cases.
Yuquan LI   +7 more
doaj   +1 more source