Results 11 to 20 of about 157,516 (285)
DC-compensated current transformer [PDF]
Instrument current transformers (CTs) measure AC currents. The DC component in the measured current can saturate the transformer and cause gross error. We use fluxgate detection and digital feedback compensation of the DC flux to suppress the overall error to 0.15%.
Pavel Ripka +2 more
openaire +4 more sources
The current transformers with split-core are used for installation in places where it is impossible to install classic current transformers. Moreover, this design allows for any measurement location change, and even switching one current transformer into
Elzbieta Lesniewska
doaj +1 more source
Shielded Electronic Current Transformer [PDF]
A current transformer with nominal ratio 10 A to 10 mA, intended for low-frequency applications, was developed. It includes an electronic device to reduce the magnetizing current, and a continuous shield in the secondary winding (coaxial cable) in order to eliminate the effect of stray capacitances. No guard-source is connected to the shield.
Slomovitz, Daniel, de Souza, Heriguatí
openaire +2 more sources
Simulation of longitudinal differential protection of transmission lines with additional stabilization and APU system [PDF]
This paper explains the algorithm for the longitudinal differential protection of transmission lines with automatic reclosing. Classic stabilization is not sufficient for avoiding of unnecessary operations caused by saturation of current transformer ...
Rajić Tomislav D., Stojanović Zoran N.
doaj +1 more source
Despite the fact that the problem of saturation of current transformers (CT) has been known for a long time, it has not lost its relevance now. Cases of malfunctioning as a result of oversaturation of CT are still recorded today.
P. Shagimardanov
doaj +1 more source
On the basis of the principle of breaker failure protection delay and the analysis of the main factors which affect the protection, a sub-station-area breaker failure and dead-zone protection technical scheme based on the current differential principle ...
Baowei Li +4 more
doaj +1 more source
Partial discharge is one of the main reasons for insulation degradation in high‐voltage apparatuses. Partial discharge is an ineluctable phenomenon that happens when a high electrical field is adjacent to an insulator. High‐frequency current transformers
Hamidreza Besharatifard +3 more
doaj +1 more source
Countermeasure to Prevent Transformer Differential Protection From False Operations
The reliability of the transformer differential protection is under threat from multiple interferences, including the inrush condition, the current transformer saturation condition, and the arc fault condition.
Penghui Liu +5 more
doaj +1 more source
The Rogowski coil current transformer is widely used in intelligent substations for its rapid response, wide bandwidth measurement, and non-magnetic saturation.
Fubin Pang +3 more
doaj +1 more source
As an important high-voltage electrical equipment in the substation, the performance stability of high-voltage current transformers is directly related to the safe operation of the power grid. The insulating medium of the traditional oil-immersed current
Zhao Fang +6 more
doaj +1 more source