Results 91 to 100 of about 8,115 (174)

Evaluation of a New Method for CyberKnife Treatment for Central Lung and Mediastinal Tumors by Tracheobronchial Tracking

open access: yesTechnology in Cancer Research & Treatment
Background CyberKnife treatment for central lung tumors and mediastinal tumors can be difficult to perform with marker less. Purpose We aimed to evaluate a novel tracheobronchial-based method (ie, tracheobronchial tracking) for the purpose of minimally ...
Toshihiro Suzuki MSc   +10 more
doaj   +1 more source

Cyberknife and benign pathologies

open access: yes, 2011
peer reviewedLa radiothérapie conventionnelle a déjà montré son efficacité pour le traitement de pathologies intracrâniennes «bénignes». Cette technique est grevée d’un certain nombre d’inconvénients.
LALLEMAND, François   +3 more
core  

CYBERKNIFE IN THE TREATMENT OF PROSTATE CANCER: A REVOLUTIONARY SYSTEM

open access: yes, 2009
The CyberKnife is a frameless advanced robotic system that uses image-guided radiotherapy (IGRT) and adaptive radiotherapy (ART) for stereotactic radiosurgery technique in intra- and extracranial lesions.
MORGIA, Giuseppe, DE RENZIS, Costantino
core   +1 more source

Intravesical prostatic protrusion as a predictor of acute urinary retention following stereotactic body radiation therapy for localised prostate cancer: a retrospective study

open access: yesOncologie
Predictors of acute urinary retention after stereotactic body radiotherapy (SBRT) for localised prostate cancer remain undefined. This study aimed to evaluate the association between intravesical prostatic protrusion (IPP) and its occurrence.
Ito Makoto   +7 more
doaj   +1 more source

CyberKnife Stereotactic Radiosurgery System for Pituitary Tumors and Pulmonary Cancer Bone Metastases: Initiating a New Chapter in Stereotactic Radiotherapy

open access: yesXiehe Yixue Zazhi
The CyberKnife, an acronym for the stereotactic radiosurgery platform, represents an image-guided stereotactic radiotherapy technique. This technology precisely delivers ionizing radiation to tissues, effectively damaging tumor cells, and is suitable for
CHENG Weishi   +5 more
doaj   +1 more source

Dose constraints for the CyberKnife prostate plan in this trial.

open access: yes, 2018
Dose constraints for the CyberKnife prostate plan in this trial.
Hiroya Shiomi (4874848)   +9 more
core   +1 more source

Commissioning and acceptance testing of a CyberKnife linear accelerator

open access: yes, 2006
Acceptance testing and commissioning of a CyberKnife robotic stereotactic radiosurgery system was performed in April 2006. The CyberKnife linear accelerator produces a photon beam of 6 MV nominal energy, without the use of a flattening filter. Clinically
Subhash C. Sharma   +2 more
core  

Point Dosimetry in Patient-specific Quality Assurance of a Robotic Radiosurgery System Using a Scintillation Detector

open access: yesJournal of Medical Physics
Purpose: Patient-specific quality assurance (QA) for CyberKnife is typically performed using micro ionization chambers and film dosimetry. However, micro ionization chambers tend to underestimate dose measurements in small radiation fields.
Kohei Okawa, Yoshifumi Hirota
doaj   +1 more source

SU-F-T-586: Pre-Treatment QA of InCise2 MLC Plans On a Cyberknife-M6 Using the Delta4 System in SBRT.

open access: yes, 2016
PURPOSE Performing pre-treatment quality assurance (QA) with the Delta4 system (ScandiDos Inc., Madison, WI) is well established for linac-based radiotherapy. This is not true when using a Cyberknife (Accuray Inc., Sunnyvale, CA) where, typically film-
Schmidhalter, Daniel   +5 more
core   +1 more source

Home - About - Disclaimer - Privacy