Experimental performance examination of a coherence technique-based numerical differential current relay for AC machine stator windings protection. [PDF]
Mahmoud RA.
europepmc +1 more source
ABSTRACT This paper presents a simplified equivalent circuit model (ECM) for the post‐arc sheath stage in DC vacuum circuit breakers and outlines the method for calculating circuit parameters using the particle‐in‐cell Monte Carlo collision (PIC‐MCC) method. The post‐arc sheath is modelled as a parallel combination of a variable resistor and a variable
Xubin Li +5 more
wiley +1 more source
Vertical Shaft Drilling Rig Frequency Conversion Electronic Control Design and Its Energy Saving and Noise Reduction Effect Analysis. [PDF]
Tian G +5 more
europepmc +1 more source
Surface Micro‐Discharge Plasma for Multiple Teeth Bleaching: Efficacy, Mechanism and Safety
ABSTRACT Hydrogen peroxide (H2O2) is the commonly‐used bleaching chemical in clinical practice, but its excessive concentrations can cause tooth damage. Atmospheric pressure cold plasma is considered a promising new technique for tooth bleaching. Surface micro‐discharge (SMD) devices can generate large‐scale plasma, which holds potential for treating ...
Ruike Chen +7 more
wiley +1 more source
Design and Characterization of a Self-Oscillating Fluxgate-Based Current Sensor for DC Distribution System Applications. [PDF]
Chen W, Chen H, Xu H, Li L.
europepmc +1 more source
ABSTRACT Large‐capacity generator circuit breaker (GCB) based on vacuum interrupter technology is the key power equipment to ensure the safe operation of the power system. When the short‐circuit current was forced to cross zero, the large‐capacity GCB was difficult to generate a zero‐voltage environment through freewheeling, the vacuum interrupter (VI)
Xiangyu Han +8 more
wiley +1 more source
Adaptive non unit traveling wave protection algorithm for multi terminal HVDC grids. [PDF]
Raza A +6 more
europepmc +1 more source
ABSTRACT Currently, limited research exists on the structural response and protection methods of the converter transformer tank for ± 800 kV ultra‐high voltage direct current transmission project to high energy arc faults. This research investigates the dynamic response and the vulnerable areas of the ultra‐high voltage converter transformer under the ...
Ke Wang +5 more
wiley +1 more source
New multi-injection commutation topology for circuit breakers of HVDC transmission lines. [PDF]
Wadie F, Elsisi M, Eliyan T.
europepmc +1 more source
Dynamic Behaviour of Bubbles in Oil Under Electrothermal Ageing
ABSTRACT During long‐term operation of converter transformers, the internal oil–pressboard insulation undergoes irreversible degradation. Partial discharge in the weakened insulation will cause the formation of a large number of bubbles in the insulating oil.
Hongbin Wu +7 more
wiley +1 more source