Results 231 to 240 of about 1,916 (295)

Investigation of the Simplified Equivalent Circuit Model of the Post‐Arc Sheath Stage in DC Vacuum Circuit Breakers

open access: yesHigh Voltage, EarlyView.
ABSTRACT This paper presents a simplified equivalent circuit model (ECM) for the post‐arc sheath stage in DC vacuum circuit breakers and outlines the method for calculating circuit parameters using the particle‐in‐cell Monte Carlo collision (PIC‐MCC) method. The post‐arc sheath is modelled as a parallel combination of a variable resistor and a variable
Xubin Li   +5 more
wiley   +1 more source

Surface Micro‐Discharge Plasma for Multiple Teeth Bleaching: Efficacy, Mechanism and Safety

open access: yesHigh Voltage, EarlyView.
ABSTRACT Hydrogen peroxide (H2O2) is the commonly‐used bleaching chemical in clinical practice, but its excessive concentrations can cause tooth damage. Atmospheric pressure cold plasma is considered a promising new technique for tooth bleaching. Surface micro‐discharge (SMD) devices can generate large‐scale plasma, which holds potential for treating ...
Ruike Chen   +7 more
wiley   +1 more source

Post‐Arc Transient Dielectric Recovery Characteristics of Vacuum Interrupter in the Large‐Capacity Generator Circuit Breaker

open access: yesHigh Voltage, EarlyView.
ABSTRACT Large‐capacity generator circuit breaker (GCB) based on vacuum interrupter technology is the key power equipment to ensure the safe operation of the power system. When the short‐circuit current was forced to cross zero, the large‐capacity GCB was difficult to generate a zero‐voltage environment through freewheeling, the vacuum interrupter (VI)
Xiangyu Han   +8 more
wiley   +1 more source

Adaptive non unit traveling wave protection algorithm for multi terminal HVDC grids. [PDF]

open access: yesSci Rep
Raza A   +6 more
europepmc   +1 more source

Arc Resistance Enhancement of Converter Transformer Tank Through Structural Improvements: Simulation and Experimental Validation

open access: yesHigh Voltage, EarlyView.
ABSTRACT Currently, limited research exists on the structural response and protection methods of the converter transformer tank for ± 800 kV ultra‐high voltage direct current transmission project to high energy arc faults. This research investigates the dynamic response and the vulnerable areas of the ultra‐high voltage converter transformer under the ...
Ke Wang   +5 more
wiley   +1 more source

Dynamic Behaviour of Bubbles in Oil Under Electrothermal Ageing

open access: yesHigh Voltage, EarlyView.
ABSTRACT During long‐term operation of converter transformers, the internal oil–pressboard insulation undergoes irreversible degradation. Partial discharge in the weakened insulation will cause the formation of a large number of bubbles in the insulating oil.
Hongbin Wu   +7 more
wiley   +1 more source

Home - About - Disclaimer - Privacy