Results 171 to 180 of about 1,496 (223)
Comprehensive analysis of challenges and two practical methods for protective coordination of distance relays in transmission lines connected to DFIG-based wind farms. [PDF]
Shahbazzadeh R +2 more
europepmc +1 more source
Microgrid anti islanding protection scheme based on deep neural network algorithm and unscented Kalman filtering. [PDF]
Chauhdary ST +5 more
europepmc +1 more source
Development of a Multi-Channel Ultra-Wideband Electromagnetic Transient Measurement System. [PDF]
He S, Chen X, Zhang B, Song L.
europepmc +1 more source
Impedance sources (Z sources) with inherent fault protection for resilient and fire-free electricity grids. [PDF]
Peng FZ.
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
A Boost Converter Integrated With DC Circuit Breaker
IECON 2021 – 47th Annual Conference of the IEEE Industrial Electronics Society, 2021The fault protection of DC microgrids restricts the popularization and development of DC grids. DC circuit breaker is an effective solution to this problem. DC circuit breaker is usually connected in series with the converter to realize the function of DC protection.
Yuyang Liu +4 more
openaire +1 more source
2008 23rd International Symposium on Discharges and Electrical Insulation in Vacuum, 2008
The results of switching tests of a DC vacuum circuit-breaker designed for rated voltage 3.3 kV and rated current 3000A are presented. The circuit-breaker is intended for current interruption in the networks with fault currents up to 30 kA. To interrupt the direct current, the authors used a method of artificial current transition through zero in the ...
D. Alferov +5 more
openaire +1 more source
The results of switching tests of a DC vacuum circuit-breaker designed for rated voltage 3.3 kV and rated current 3000A are presented. The circuit-breaker is intended for current interruption in the networks with fault currents up to 30 kA. To interrupt the direct current, the authors used a method of artificial current transition through zero in the ...
D. Alferov +5 more
openaire +1 more source
Design and Simulation of a Bidirectional DC Circuit Breaker
IECON 2020 The 46th Annual Conference of the IEEE Industrial Electronics Society, 2020In recent years, DC microgrid has been developing continuously and its application range is more and more wide, which puts forward higher requirements for its protection. This paper proposes a bidirectional DC solid-state circuit breaker (SSCB), which allows power to flow bidirectionally and can be used in bidirectional DC microgrid protection ...
Yufei Tao 0002 +3 more
openaire +1 more source
A study on Low-Voltage DC circuit breakers
2013 IEEE International Symposium on Industrial Electronics, 2013Recently, DC distribution systems become hot issues since DC type loads increase rapidly according to the expansion of IT equipment such as computers, servers, and digital devices; DC type loads will cover 50% for all electricity loads in 2020 which was mere 10% in 2000 [1,2].
Sungmin Lee, Hyosung-Kim
openaire +1 more source
A New Z-Source DC Circuit Breaker
IEEE Transactions on Power Electronics, 2010A novel type of circuit breaker is introduced for operation at medium-voltage dc with future naval ship power systems as a targeted application. The breaker utilizes a z-source LC circuit in order to automatically commutate a main-path SCR during a fault.
Keith A. Corzine, Robert W. Ashton
openaire +1 more source