Results 161 to 170 of about 1,289,411 (215)
Enhanced Wear Resistance and Thermal Dissipation of Copper-Graphene Composite Coatings via Pulsed Electrodeposition for Circuit Breaker Applications. [PDF]
Almonti D +3 more
europepmc +1 more source
Improved active current limiting control for flexible DC power grid to consider the effects of selective and higher fault resistance. [PDF]
Qin X, Hou J, Fan Y, Song G, Wu X.
europepmc +1 more source
Smart technique for calculating fault current model parameters using short circuit current measurements. [PDF]
Mahmoud RA, Malik OP, Fayek WM.
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
A Boost Converter Integrated With DC Circuit Breaker
IECON 2021 – 47th Annual Conference of the IEEE Industrial Electronics Society, 2021The fault protection of DC microgrids restricts the popularization and development of DC grids. DC circuit breaker is an effective solution to this problem. DC circuit breaker is usually connected in series with the converter to realize the function of DC protection.
Yuyang Liu +4 more
openaire +1 more source
2008 23rd International Symposium on Discharges and Electrical Insulation in Vacuum, 2008
The results of switching tests of a DC vacuum circuit-breaker designed for rated voltage 3.3 kV and rated current 3000A are presented. The circuit-breaker is intended for current interruption in the networks with fault currents up to 30 kA. To interrupt the direct current, the authors used a method of artificial current transition through zero in the ...
D. Alferov +5 more
openaire +1 more source
The results of switching tests of a DC vacuum circuit-breaker designed for rated voltage 3.3 kV and rated current 3000A are presented. The circuit-breaker is intended for current interruption in the networks with fault currents up to 30 kA. To interrupt the direct current, the authors used a method of artificial current transition through zero in the ...
D. Alferov +5 more
openaire +1 more source
Design and Simulation of a Bidirectional DC Circuit Breaker
IECON 2020 The 46th Annual Conference of the IEEE Industrial Electronics Society, 2020In recent years, DC microgrid has been developing continuously and its application range is more and more wide, which puts forward higher requirements for its protection. This paper proposes a bidirectional DC solid-state circuit breaker (SSCB), which allows power to flow bidirectionally and can be used in bidirectional DC microgrid protection ...
Yufei Tao 0002 +3 more
openaire +2 more sources
A study on Low-Voltage DC circuit breakers
2013 IEEE International Symposium on Industrial Electronics, 2013Recently, DC distribution systems become hot issues since DC type loads increase rapidly according to the expansion of IT equipment such as computers, servers, and digital devices; DC type loads will cover 50% for all electricity loads in 2020 which was mere 10% in 2000 [1,2].
Sungmin Lee, Hyosung-Kim
openaire +2 more sources
Modeling for series arc of DC circuit breaker
2017 IEEE 6th International Conference on Renewable Energy Research and Applications (ICRERA), 2017In electric distribution systems, a series arc occurs when a load and a power source are disconnected from a connector such as a circuit breaker, a socket–plug, or a coupler. In dc systems, the arc is not extinguished unless the arc current decreases to zero. Sustaining plasma arc current can cause huge fire disasters. To cope with the arc faults in dc
Yong-Jung Kim, Hyosung Kim
openaire +1 more source
A New Z-Source DC Circuit Breaker
IEEE Transactions on Power Electronics, 2010A novel type of circuit breaker is introduced for operation at medium-voltage dc with future naval ship power systems as a targeted application. The breaker utilizes a z-source LC circuit in order to automatically commutate a main-path SCR during a fault.
Keith A. Corzine, Robert W. Ashton
openaire +1 more source