Results 11 to 20 of about 1,289,411 (215)
Operating DC Circuit Breakers With MMC [PDF]
High Voltage Direct Current (HVDC) grids may be protected from dc faults through the application of HVDC circuit breakers. Recent advances in dc circuit breaker technologies may allow faults in the dc grid to be cleared without a permanent loss of power to the connected ac grids.
Oliver Cwikowski +4 more
openaire +4 more sources
Parameters of DC high-speed circuit-breakers
DC high-speed circuit-breakers (HSCB) are the basic protection to cut off short-circuit and overload currents. People’s and railway infrastructure devices’ safety depend on their reliability and parameters.
Rojek Artur
doaj +2 more sources
Interlink Hybrid DC Circuit Breaker [PDF]
—To protect HVDC grids from DC faults, the concept of a hybrid DC circuit breaker is widely accepted due to its low conduction losses and fast interruption speed. For a well-built DC grid, a massive number of hybrid DC circuit breakers have to be installed. This will lead to high capital costs.
Chuanyue Li +2 more
openaire +5 more sources
Advanced Test Circuit for DC Circuit Breakers
QC ...
Augustin, Tim +2 more
core +4 more sources
A Dual-Bridge Hybrid DC Circuit Breaker [PDF]
Various DC circuit breakers (DCCBs) have been widely proposed for the DC fault protection of high-voltage direct-current (HVDC) grids. In recent years, hybrid DCCBs (HCBs) have been paid significant attentions due to their features of low power losses and fast dynamic response.
Hanwen Zhang 0005 +4 more
openaire +2 more sources
Determination of protection system requirements for DC UAV electrical power networks for enhanced capability and survivability [PDF]
A growing number of designs of future Unmanned Aerial Vehicle (UAV) applications utilise dc for the primary power distribution method. Such systems typically employ large numbers of power electronic converters as interfaces for novel loads and generators.
Burt, Graeme +3 more
core +4 more sources
Superconducting Interface for a DC Circuit Breaker [PDF]
High voltage direct current (HVDC) circuit breakers are a key technology to enable fault management for multi terminal DC (MTDC) networks. DC circuit breakers using superconductors for current limiting have been proposed previously and experimentally tested at low voltage levels.
Pei, Xiaoze +2 more
openaire +1 more source
In hierarchically connected UHV DC projects, the 1000 kV AC filter sub-bank in converter station is provided with two 500 kV circuit breakers. To determine the test DC component decay time constant when breakers break short-circuit current, relevant DC ...
Li Zhenqiang +3 more
doaj +1 more source
The energetics of gas flow and contact erosion during short circuit arcing [PDF]
The processes governing the movement of short circuit arcs in circuit breakers are complex and variable and the detailed understanding of these processes is incomplete.
Weaver, P.M. +2 more
core +1 more source
Arc motion and gas flow in current limiting circuit breakers operating with a low contact switching velocity [PDF]
Arc motion in low voltage (240 VAC) high current (10/sup 3/-10/sup 4/A.) current limiting-circuit breakers is dominated by arc root mobility. The mobility is influenced by the gas flow and gas composition in the contact region, but there is little ...
Weaver, P.M. +2 more
core +1 more source