Results 41 to 50 of about 670 (185)

DC interruption characteristic of vacuum circuit breaker

open access: yesElectrical Engineering in Japan, 2005
AbstractA high‐speed vacuum circuit breaker (HSVCB) has been investigated. HSVCB makes high‐frequency current superimposed on a fault current so that the current is forced to be zero and is interrupted. Its interruption performance is considered to be dependent on the rate of change of the current (di/dt). As a fundamental research, we investigated the
Odaka, Hiromi   +5 more
openaire   +2 more sources

Prestrike characteristics and dynamic dielectric breakdown mechanism of double-break vacuum circuit breakers under AC and DC voltages [PDF]

open access: yesAIP Advances
Understanding the prestrike characteristics of vacuum circuit breakers is essential for phase-controlled closing and insulation design. Double-break vacuum circuit breakers (DBVCBs) are used in reactive power compensation, but most studies of their ...
Hannan Shan   +6 more
doaj   +1 more source

A Comprehensive Review of Fault‐Current Limiter Technologies for Smart and Resilient Power Systems

open access: yesEnergy Science &Engineering, EarlyView.
This review compares superconducting, solid‐state, and hybrid fault‐current limiters (FCLs) for modern alternating current, direct current, and hybrid grids. It shows that optimal FCL selection depends on fault characteristics, network configuration, voltage level, protection coordination, and resilience requirements rather than on a universally ...
Abdelrahman Farghly   +5 more
wiley   +1 more source

Analysis of the Feasibility of Using Hybrid DC Circuit Breakers with Forced Switching for Parallel Connections

open access: yesEnergies
The use of advanced switching technologies, including hybrid and fully semiconductor-based circuit breakers, enables a significant reduction in the prospective short-circuit current. This enhances the level of circuit protection by minimizing thermal and
Łukasz Nowak   +2 more
doaj   +1 more source

Design Approaches for Oxygen Reduction Systems for Warehouse Storage Applications

open access: yesFire and Materials, EarlyView.
ABSTRACT Oxygen reduction systems (ORS) are protection systems, with a design protection objective to limit fire spread beyond the point of ignition. Research has shown that the prescriptive design methods, in VdS 3527, EN 16750, and ISO 20338, are not appropriate as prescriptive design methods as they result in insufficient protection levels.
Martin Nilsson   +3 more
wiley   +1 more source

Meniscus‐guided organic semiconductor single crystals: From fluid dynamics to morphology control and multifunctional applications

open access: yesFlexMat, EarlyView.
Centered on the multiscale meniscus, this review dissects mass transport in meniscus‐guided coating into parallel and lateral components. By analyzing the balance of multiple factors during crystallization, it establishes a clear morphology‐performance relationship.
Yumeng Wang   +7 more
wiley   +1 more source

A comprehensive review of impedance source network DC circuit breaker topologies

open access: yesCogent Engineering
Dc microgrids (MG) have drawn more attention due to the demand for renewable energy sources, energy storage devices in distributed generation, and the separation of DC loads requiring more power converters.
Marwan R. Abed   +3 more
doaj   +1 more source

Surface Micro‐Discharge Plasma for Multiple Teeth Bleaching: Efficacy, Mechanism and Safety

open access: yesHigh Voltage, EarlyView.
ABSTRACT Hydrogen peroxide (H2O2) is the commonly‐used bleaching chemical in clinical practice, but its excessive concentrations can cause tooth damage. Atmospheric pressure cold plasma is considered a promising new technique for tooth bleaching. Surface micro‐discharge (SMD) devices can generate large‐scale plasma, which holds potential for treating ...
Ruike Chen   +7 more
wiley   +1 more source

Optimisation of commutation circuit parameters for DC vacuum circuit breakers

open access: yesThe Journal of Engineering, 2019
As the environmental problems caused by the consumption of the non-renewable fossil energy are getting increasingly serious, the new energy power generation has received wide attentions.
Deen Yu, Hai Chen, Wei Liu, Xiaoming Liu
doaj   +1 more source

Smart protection system for identification and localisation of faults in multi-terminal DC microgrid

open access: yesIET Smart Grid, 2020
DC microgrid provides the horizontal infrastructures to integrate distributed generation (DG) and loads. Unlike traditional AC systems, DC systems cannot survive or sustain high magnitude fault currents. It makes locating faults very difficult.
Rajeev Kumar Chauhan   +2 more
doaj   +1 more source

Home - About - Disclaimer - Privacy