Results 41 to 50 of about 639 (185)

RES‐AD: An AutoML‐Driven Robust Ensemble Framework for Real‐Time Anomaly Detection and Energy Forecasting in Smart Grids

open access: yesCAAI Transactions on Intelligence Technology, EarlyView.
ABSTRACT Accurate load forecasting and reliable anomaly detection are critical for the stable operation of modern smart grids (SGs), which increasingly rely on cyber‐connected infrastructures. However, the integration of smart metres and two‐way communication exposes SGs to data integrity attacks that can manipulate consumption measurements, degrade ...
Murad Ali Khan   +4 more
wiley   +1 more source

Investigation of the Simplified Equivalent Circuit Model of the Post‐Arc Sheath Stage in DC Vacuum Circuit Breakers

open access: yesHigh Voltage, EarlyView.
ABSTRACT This paper presents a simplified equivalent circuit model (ECM) for the post‐arc sheath stage in DC vacuum circuit breakers and outlines the method for calculating circuit parameters using the particle‐in‐cell Monte Carlo collision (PIC‐MCC) method. The post‐arc sheath is modelled as a parallel combination of a variable resistor and a variable
Xubin Li   +5 more
wiley   +1 more source

Surface Micro‐Discharge Plasma for Multiple Teeth Bleaching: Efficacy, Mechanism and Safety

open access: yesHigh Voltage, EarlyView.
ABSTRACT Hydrogen peroxide (H2O2) is the commonly‐used bleaching chemical in clinical practice, but its excessive concentrations can cause tooth damage. Atmospheric pressure cold plasma is considered a promising new technique for tooth bleaching. Surface micro‐discharge (SMD) devices can generate large‐scale plasma, which holds potential for treating ...
Ruike Chen   +7 more
wiley   +1 more source

T-Type Modular DC Circuit Breaker (T-Breaker) as a Compensator for Future DC Grids

open access: yesIEEE Access, 2023
When ac and dc microgrids get exposed to load power changes or voltage transients, instability could occur owing to constant power loads’ (CPLs) behaviour. CPL has the negative impedance behaviour which is the reason behind such instability. A flexible alternating current transmission system (FACTS) devices are used in ac grid to help improve ...
Faisal Alsaif   +5 more
openaire   +2 more sources

Interruption characteristics of self-powered hybrid DC circuit breaker with synergistic effect of step-down and divided current

open access: yesInternational Journal of Electrical Power & Energy Systems
The DC voltage level of photovoltaic and PEDF applications have continuously advanced, reaching up to DC3000V. This presents new requirements for DC circuit breakers operating at higher voltages (>DC1500V) to ensure effective fault protection in the DC ...
Jianning Yin   +4 more
doaj   +1 more source

Short-Circuit Fault Current Modeling of a DC Light Rail System with a Wayside Energy Storage Device

open access: yesEnergies, 2022
This paper proposes a simulation model to calculate short-circuit fault currents in a DC light rail system with a wayside energy storage device. The simulation model was built in MATLAB/Simulink using the electrical information required to define a ...
Petru Valentin Radu   +3 more
doaj   +1 more source

Post‐Arc Transient Dielectric Recovery Characteristics of Vacuum Interrupter in the Large‐Capacity Generator Circuit Breaker

open access: yesHigh Voltage, EarlyView.
ABSTRACT Large‐capacity generator circuit breaker (GCB) based on vacuum interrupter technology is the key power equipment to ensure the safe operation of the power system. When the short‐circuit current was forced to cross zero, the large‐capacity GCB was difficult to generate a zero‐voltage environment through freewheeling, the vacuum interrupter (VI)
Xiangyu Han   +8 more
wiley   +1 more source

Arc Resistance Enhancement of Converter Transformer Tank Through Structural Improvements: Simulation and Experimental Validation

open access: yesHigh Voltage, EarlyView.
ABSTRACT Currently, limited research exists on the structural response and protection methods of the converter transformer tank for ± 800 kV ultra‐high voltage direct current transmission project to high energy arc faults. This research investigates the dynamic response and the vulnerable areas of the ultra‐high voltage converter transformer under the ...
Ke Wang   +5 more
wiley   +1 more source

Advancements in Z-Source Solid-State Circuit Breakers for Enhanced Protection of DC Distribution Networks: A Comprehensive Review

open access: yesActive and Passive Electronic Components
DC technologies constitute essential components within the scope of DC distribution networks. All DC networks confront inherent threats, such as DC short-circuit faults, necessitating robust protective measures.
Sabah Daniar   +1 more
doaj   +1 more source

Comparison of Dielectric Recovery After Arc Burning in SF6 Gas and Its Potential Alternatives

open access: yesHigh Voltage, EarlyView.
ABSTRACT Although sulphur hexafluoride (SF6) exhibits exceptional insulating properties, it is a potent greenhouse gas. Therefore, studying alternatives to SF6 is critical for developing environmentally friendly high‐voltage electrical equipment.
Ziqi Liu   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy