Results 51 to 60 of about 1,289,411 (215)
ABSTRACT Accurate load forecasting and reliable anomaly detection are critical for the stable operation of modern smart grids (SGs), which increasingly rely on cyber‐connected infrastructures. However, the integration of smart metres and two‐way communication exposes SGs to data integrity attacks that can manipulate consumption measurements, degrade ...
Murad Ali Khan +4 more
wiley +1 more source
Study on working condition of 750 kV AC filter breaker in ± 1100 kV UHVDC system
In this article, the Changji-Guquan ± 1100 kV ultra-high voltage direct current (UHVDC) system has been established by PSCAD software, especially for the arc of the circuit breakers.
Zexin Zhao +4 more
doaj +1 more source
Surface Micro‐Discharge Plasma for Multiple Teeth Bleaching: Efficacy, Mechanism and Safety
ABSTRACT Hydrogen peroxide (H2O2) is the commonly‐used bleaching chemical in clinical practice, but its excessive concentrations can cause tooth damage. Atmospheric pressure cold plasma is considered a promising new technique for tooth bleaching. Surface micro‐discharge (SMD) devices can generate large‐scale plasma, which holds potential for treating ...
Ruike Chen +7 more
wiley +1 more source
ABSTRACT Currently, limited research exists on the structural response and protection methods of the converter transformer tank for ± 800 kV ultra‐high voltage direct current transmission project to high energy arc faults. This research investigates the dynamic response and the vulnerable areas of the ultra‐high voltage converter transformer under the ...
Ke Wang +5 more
wiley +1 more source
Comparison of Dielectric Recovery After Arc Burning in SF6 Gas and Its Potential Alternatives
ABSTRACT Although sulphur hexafluoride (SF6) exhibits exceptional insulating properties, it is a potent greenhouse gas. Therefore, studying alternatives to SF6 is critical for developing environmentally friendly high‐voltage electrical equipment.
Ziqi Liu +4 more
wiley +1 more source
ABSTRACT This paper investigates the generation mechanism of quasi‐power‐frequency resonant overvoltage triggered by multiple lightning strikes in high‐voltage alternating current (HVAC) systems equipped with shunt reactors. Based on field measurements from a 500 kV AC system, equivalent and simplified circuit models have been established to analyse ...
Tao Liang +7 more
wiley +1 more source
The DC voltage level of photovoltaic and PEDF applications have continuously advanced, reaching up to DC3000V. This presents new requirements for DC circuit breakers operating at higher voltages (>DC1500V) to ensure effective fault protection in the DC ...
Jianning Yin +4 more
doaj +1 more source
Short-Circuit Fault Current Modeling of a DC Light Rail System with a Wayside Energy Storage Device
This paper proposes a simulation model to calculate short-circuit fault currents in a DC light rail system with a wayside energy storage device. The simulation model was built in MATLAB/Simulink using the electrical information required to define a ...
Petru Valentin Radu +3 more
doaj +1 more source
A coupled Saber–TCAD–thermo‐mechanical simulation framework is proposed to evaluate microscopic stresses in SiC MOSFETs under overcurrent operation. Ultrahigh gate‐voltage driving reduces thermal and mechanical stress but increases gate oxide electric‐field stress, revealing a reliability tradeoff for DC solid‐state circuit breakers.
Bin Yu +3 more
wiley +1 more source
T-Type Modular DC Circuit Breaker (T-Breaker) as a Compensator for Future DC Grids
When ac and dc microgrids get exposed to load power changes or voltage transients, instability could occur owing to constant power loads’ (CPLs) behaviour. CPL has the negative impedance behaviour which is the reason behind such instability. A flexible alternating current transmission system (FACTS) devices are used in ac grid to help improve ...
Faisal Alsaif +5 more
openaire +2 more sources