Results 51 to 60 of about 677 (213)
This paper proposes a statistical DGA diagnosis method to evaluate the occurrence and type of the discharge starting stage of the converter transformer based on a statistical analysis of the gas generation amount in the converter transformer oil during operation.
Kwang Hui An +2 more
wiley +1 more source
Sugarcane‐derived ethanol is a key renewable fuel, contributing to energy security and climate change mitigation by replacing fossil‐based fuels in tropical regions. This article introduces an integrated exergy–economic–environmental–life cycle assessment (LCA) framework for a sugarcane cogeneration system, providing novel benchmarks and optimization ...
Eduardo J. C. Cavalcanti +6 more
wiley +1 more source
Bubbles as a Means for the Deaeration of Water Bodies
Occasional dissolved-air supersaturation - such as may occur, for instance, downstream of dams - is harmful to fish because it causes gas bubble disease. A counterintuitive but effective means of reducing dissolved air content is the injection of bubbles in the supersaturated water.
Zhang, Yuhang +2 more
openaire +1 more source
Online monitoring of nuclear power plant (NPP) operational status is critical for ensuring safe and reliable operation. Given the complexity of NPP systems and the large number of variables to be monitored, conventional monitoring approaches which rely heavily on operators’ experience are facing significant challenges in fault detection and ...
Zhiyun Liu +3 more
wiley +1 more source
Novel Approach to Improve Deaerator Operations
Venting from deaerator removes dissolved oxygen and carbon dioxide in the feed water before it reaches the steam boiler. For steam boilers requiring raw make-up water containing dissolved oxygen, typical deaerator vent rate of half to one percent of ...
Tung, P.
core +1 more source
How are exergy, exergoeconomic, and carbon capture analyses performed in a new F‐class combined cycle power plant (CCPP)? ABSTRACT Efficient energy use and new resource development are important due to increasing global energy demand from population growth.
Mostafa Baghsheikhi +2 more
wiley +1 more source
By combining orthogonal experimental design with simulation, the optimal peak shaving scheme for the system was quickly identified among the 576 proposed working fluid extraction schemes for the coupled molten salt thermal storage system of thermal power units.
Yunlong Zhou +5 more
wiley +1 more source
Membrane water deaerator investigation [PDF]
The purpose of the membrane water deaerator program was to develop data on a breadboard hollow fiber membrane unit that removes both dissolved and evolved gas from a water transfer system in order to: (1) assure a hard fill of the EVLSS expendable water
Strumpf, H., Elam, J., Ruder, J.
core
Trip transient analysis on the main feedwater pump of HPR1000
In PWR, the main feedwater pump is one of the main equipment in the secondary side which has an important impact on the safe and stable operation of the entire power plant, and then directly affecting the output and availability of the unit. Based on the
Yang Jianjun +3 more
doaj +1 more source
Condenser and Deaerator Control using Fuzzy-Neural Technique [PDF]
A model reference adaptive control of condenser and deaerator of steam power plant ispresented. A fuzzy-neural identification is constructed as an integral part of the fuzzy-neuralcontroller.
Abduladhem Abdulkareem Ali +1 more
doaj